11
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF621
5. How to Wire Your Ceiling Fan
(continued)
NOTE: CEILING COVER
OMITTED FOR CLARITY.
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
WHITE SUPPLY
(NEUTRAL)
WHITE FAN WIRE
BLACK SUPPLY
(HOT)
BLACK
FAN WIRE
BLUE FAN WIRE
Figure 15
KNURLED KNOBS (2)
LOCKWASHERS (2)
THREADED STUDS (2)
CEILING COVER
Figure 16
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the ceiling cover and the ceiling.
WARNING
!
5.3
Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
5.4
Lift the ceiling cover up to the threaded studs and turn
until studs protrude through the holes in the ceiling
cover (Figure 16).
5.5
Secure the ceiling cover in place by sliding lockwashers
over the threaded studs and installing the two knurled
knobs (supplied). (Figure 16). Tighten the knurled
knobs securely until the ceiling cover fits snugly against
the ceiling and the hole in the ceiling cover is clear of
the downrod. Your fan is now wired to be turned on and
off from the fan switch.
5.2
Securely connect the fan motor white wire to the supply
white (neutral) wire using wire connector supplied
(Figure 15). Securely connect the fan motor black wire
and blue wire to the supply black (hot) wire using wire
connector supplied (Figure 15). After connections have
been made, turn leads upward and carefully push leads
into the outlet box, with the white and green leads on
one side of the outlet box and the blue and black leads
on the other side of the outlet box.