background image

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

7

How to Wire Your

Ceiling Fan

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.

WARNING

!

1. If you are going to use an Emerson Remote

Control/Receiver or Wall Control/Receiver to
operate your ceiling fan, wire your fan in
accordance with the Control/Receiver
Owner’s Manual. (NOTE: The wire from the
uplight harness is orange instead of yellow.)
After wiring, return to Step 4 below.

2. If you are going to use two wall switches or

Emerson Fan/Light Controls, you will need a
three-wire (with ground) conductor cable
between the ceiling and wall outlet boxes.
This will allow you to operate the uplight and
optional Emerson Light Fixture (if installed)
from one switch/control and the ceiling fan
from a separate switch/control. (Refer to the
Emerson Fan/Light Control Owner’s Manual.)
Refer to Figure 10 and proceed as follows:
a. Connect the green grounding lead from

the hanger ball and the green grounding
lead from the hanger bracket to the
supply grounding conductor  (this may be
a bare wire or wire with green colored
insulation). Securely connect wires with a
wire connector (supplied).

b. Securely connect the fan motor white wire

to the supply white (neutral) wire using a
wire connector (supplied). 

c. Securely connect the fan motor black wire

to the supply black (hot) wire using a wire
connector (supplied).

d. Securely connect the fan motor blue wire

to the supply red (hot) wire using a wire
connector (supplied). 

e. After connections have been made,

separate the white and green wires from
the black, blue and red wires.

f. Carefully turn the wires upward and insert

them up through the open side of the
hanger bracket and into the outlet box.
Push the green and white wires into
one side of the outlet box; push the black,
blue and red wires into the other
side of the outlet box.

3. If you are going to use a single wall switch to

control your ceiling fan, uplight, and optional
Emerson Light Fixture (if installed)
simultaneously, you will need a standard
two-wire (with ground) conductor cable
between the ceiling and wall outlet boxes.
The fan speed and uplight can then be
operated from the pull chain switches in the
switch housing; the optional light fixture can
be operated from the light fixture switch.
Refer to Figure 11 and proceed as follows:
a Connect the green grounding lead from

the hanger ball and the green grounding
lead from the hanger bracket to the
supply grounding conductor (this may be
a bare wire or wire with green colored
insulation). Securely connect wires with a
wire connector (supplied).

b. Securely connect the fan motor white wire

to the supply white (neutral) wire using a
wire connector (supplied). 

c. Securely connect the fan motor black

wire and blue wire to the supply black (hot)
wire using a wire connector (supplied).

d. After connections have been made,

separate the white and green wires from
the black and blue wires.

e. Carefully turn the wires upward and insert

them up through the open side of the
hanger bracket and into the outlet box.
Push the green and white wires into one
side of the outlet box; push the black and
blue wires into the other side of the outlet
box.

BLACK

BLACK FAN WIRE

LISTED OUTLET BOX

LIGHT

CONTROL

GREEN WIRE
(GROUND) 
FROM 
HANGER 
BRACKET

TO 120 
VOLT
SUPPLY

WHITE

GROUND

GREEN WIRE (GROUND)
FROM  HANGER BALL

GROUND
WIRE

WHT.

EMERSON FAN CONTROL

BLACK
(HOT)

BLUE

RED

GROUND

THREE-CONDUCTOR CABLE (WITH 
GROUND) BETWEEN CEILING AND 
WALL OUTLET BOXES

LISTED WIRE CONNECTOR (4)

Figure 10

BLACK FAN WIRE

LISTED OUTLET BOX

GENERAL USE 

ON/OFF

WALL SWITCH

GREEN WIRE
(GROUND) 
FROM 
HANGER 
BRACKET

TO 120 
VOLT
SUPPLY

WHITE

GROUND

GREEN WIRE (GROUND)
FROM  HANGER BALL

GROUND
WIRE

WHT.

BLACK
(HOT)

BLUE

BLACK

GROUND

TWO-CONDUCTOR CABLE (WITH 
GROUND) BETWEEN CEILING AND 
WALL OUTLET BOXES

LISTED WIRE CONNECTOR (3)

Figure 11

Check to see that all connections are tight,
including ground, and that no bare wire is visible
at the wire connectors, except for the ground wire.
Do not operate fan until blades are in place. Noise
and fan damage could result.

WARNING

!

Check to see that all connections are tight,
including ground, and that no bare wire is visible
at the wire connectors, except for the ground wire.
Do not operate fan until blades are in place. Noise
and fan damage could result.

WARNING

!

Содержание ATHENIAN CF2400AB00

Страница 1: ...eturn the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What...

Страница 2: ...ed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be moun...

Страница 3: ...urled knobs 6 Four lockwashers 7 Four wire connectors 8 Two pull chain pendants 3 9 Two couplings 10 One hairpin clip 11 One clevis pin 12 Eleven 10 32 x 5 8 oval head screws 13 Sixteen 10 32 x 3 8 Phillips pan head screws 14 Sixteen 10 flat washers 15 Three 8 32 x 3 8 pan head screws NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are ...

Страница 4: ...d to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid possible ...

Страница 5: ...he downrod Be sure the cover is oriented correctly with the large opening at the top Figure 4 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 2 could result in the fan falling WARNING LOCKWASHER 2 KNURLED KNOB 2 MOTOR COUPLING MOTOR COVER 1 THREAD...

Страница 6: ...nd seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 9 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 8 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING To reduce the risk of personal injury...

Страница 7: ...ll switch to control your ceiling fan uplight and optional Emerson Light Fixture if installed simultaneously you will need a standard two wire with ground conductor cable between the ceiling and wall outlet boxes The fan speed and uplight can then be operated from the pull chain switches in the switch housing the optional light fixture can be operated from the light fixture switch Refer to Figure ...

Страница 8: ...ossible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING CEILING COVER THREADED STUDS 2 KNURLED KNOB 2 LOCKWASHER 2 Figure 12 SWITCH HOUSING COVER COVER PLATE FINIAL NUT Figure 13 8 32 x 3 8 PAN HEAD SCREWS 3 SWITCH HOUSING COVER Figure 15 9 Position the switch housing cover so that the tab on t...

Страница 9: ...or this fan could result in fire shock and personal injury WARNING WARNING 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the 4 position speed control switch pull chain The operating sequence is as follows THREE SPEED 1st Pull HIGH 3rd Pull Low 2nd Pull Medium 4th Pull OFF 3 If airflow is desired...

Страница 10: ...housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is not tightened 1 Raise coupling cover and tighten setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball downrod assembly is loose 3 Screws securing fan blade flanges to 3 Check to be sure screws which...

Страница 11: ...Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 ...

Страница 12: ...3 761621 23 761621 27 761621 25 761621 21 761621 24 761621 17 22 Capacitor Aux 10 uF 762242 762242 762242 762242 762242 762242 762242 23 Motor 762508 762508 762508 762508 762508 762508 762508 24 Hub Motor 760601 760601 760601 760601 760601 760601 760601 25 Flange Set Blade full set for one fan 762540 5 762540 4 762540 13 762540 12 762540 8 762540 11 762540 1 26 Housing Assembly Switch 762542 76254...

Отзывы: