Tools Needed for Assembly

One Phillips head screwdriver

One wire stripper

Three wire connectors 

(supplied)

One stepladder

Four T8 25-watt 

(max.)

candelabra base bulbs 

(supplied)

MATERIALS

Wiring, outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
sizes:

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is
completed, place a check mark in the box. This will insure that all steps have been
completed and will be helpful in finding your place should you be interrupted.

1. Open styrofoam unit containing fan. Remove top

half of styrofoam unit. Remove parts and check to
see that you have received the following parts:

NOTE: If you are uncertain of part description,
refer to exploded view illustration.

a. Fan motor and housing assembly
b. One motor cover
c. Once ceiling cover
d. Five blade flanges
e. One hanger bracket
f. One hanger ball/downrod assembly
g. One switch housing cover
h. One cover plate
i. One finial nut
j. One uplight lead assembly (used only for

remote control operation)

k. Four T8 25-watt candelabra base bulbs
l. One loose parts bag containing:

1. One 5/16-18 x 1/4” setscrew
2. One setscrew wrench
3. Two 1” threaded studs
4. Two 1-1/4” threaded studs
5. Four knurled knobs
6. Four lockwashers
7. Four wire connectors
8. Two pull chain pendants

3

9.

Two couplings

10. One hairpin clip
11. One clevis pin
12. Eleven 10-32 x 5/8” oval head screws
13. Sixteen 10-32 x 3/8” Phillips pan head

screws

14. Sixteen #10 flat washers
15. Three 8-32 x 3/8” pan head screws

NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.

Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 7). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.

WARNING

!

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

WARNING

!

WARNING

!

This Manual Is Designed to Make it as Easy as Possible for You to

Assemble, Install, Operate and Maintain Your Ceiling Fan

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

FAN MOTOR 
AND HOUSING
ASSEMBLY

BLADE
FLANGES

FINIAL
NUT

HANGER
BRACKET

SWITCH 
HOUSING 
COVER

HANGER BALL/
DOWNROD
ASSEMBLY

LOOSE
PARTS
BAG

COVER 
PLATE

CEILING 
COVER

MOTOR 
COVER

Содержание ATHENIAN CF2400AB00

Страница 1: ...eturn the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What...

Страница 2: ...ed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be moun...

Страница 3: ...urled knobs 6 Four lockwashers 7 Four wire connectors 8 Two pull chain pendants 3 9 Two couplings 10 One hairpin clip 11 One clevis pin 12 Eleven 10 32 x 5 8 oval head screws 13 Sixteen 10 32 x 3 8 Phillips pan head screws 14 Sixteen 10 flat washers 15 Three 8 32 x 3 8 pan head screws NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are ...

Страница 4: ...d to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To avoid possible ...

Страница 5: ...he downrod Be sure the cover is oriented correctly with the large opening at the top Figure 4 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed as shown in Figure 2 could result in the fan falling WARNING LOCKWASHER 2 KNURLED KNOB 2 MOTOR COUPLING MOTOR COVER 1 THREAD...

Страница 6: ...nd seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 9 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 8 The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support WARNING To reduce the risk of personal injury...

Страница 7: ...ll switch to control your ceiling fan uplight and optional Emerson Light Fixture if installed simultaneously you will need a standard two wire with ground conductor cable between the ceiling and wall outlet boxes The fan speed and uplight can then be operated from the pull chain switches in the switch housing the optional light fixture can be operated from the light fixture switch Refer to Figure ...

Страница 8: ...ossible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING CEILING COVER THREADED STUDS 2 KNURLED KNOB 2 LOCKWASHER 2 Figure 12 SWITCH HOUSING COVER COVER PLATE FINIAL NUT Figure 13 8 32 x 3 8 PAN HEAD SCREWS 3 SWITCH HOUSING COVER Figure 15 9 Position the switch housing cover so that the tab on t...

Страница 9: ...or this fan could result in fire shock and personal injury WARNING WARNING 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the 4 position speed control switch pull chain The operating sequence is as follows THREE SPEED 1st Pull HIGH 3rd Pull Low 2nd Pull Medium 4th Pull OFF 3 If airflow is desired...

Страница 10: ...housing 5 Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles 1 Setscrew in motor coupling is not tightened 1 Raise coupling cover and tighten setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly 2 Tighten the setscrew in the hanger ball downrod assembly is loose 3 Screws securing fan blade flanges to 3 Check to be sure screws which...

Страница 11: ...Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 ...

Страница 12: ...3 761621 23 761621 27 761621 25 761621 21 761621 24 761621 17 22 Capacitor Aux 10 uF 762242 762242 762242 762242 762242 762242 762242 23 Motor 762508 762508 762508 762508 762508 762508 762508 24 Hub Motor 760601 760601 760601 760601 760601 760601 760601 25 Flange Set Blade full set for one fan 762540 5 762540 4 762540 13 762540 12 762540 8 762540 11 762540 1 26 Housing Assembly Switch 762542 76254...

Отзывы: