background image

23

emersonfans.com

Please contact 1-800-654-3545 for further assistance

ETL Model No.: CF717

What The Limited Warranty Covers:

This limited warranty is offered by Air Comfort Products division of Emerson Electric Co. (

"Emerson" "we"

or 

"us"

) located at the address stated below to the original

retail purchaser (

"you"

or 

"your"

) of an Emerson Air Comfort Ceiling Fan product (

"Emerson Ceiling Fan"

) and covers the motor and the other components and

accessories of the Emerson Ceiling Fan against all defects in workmanship and materials.

What The Period Of Coverage Is:

This limited warranty will cover the Emerson Ceiling Fan motor for the expected lifetime of your Emerson Ceiling Fan (when operated in accordance with your Owner's
Manual or other instructions provided by Emerson to you with the Emerson Ceiling Fan). All other components and accessories of the Emerson Ceiling Fan are covered
by this limited warranty for a period of one (1) year from its date of original retail purchase. ANY IMPLIED WARRANTY, INCLUDING WITHOUT LIMITATION, ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS AVAILABLE TO YOU UNDER THE LAWS OF YOUR STATE OR
PROVINCE SHALL COVER THE MOTOR FOR THE EXPECTED LIFETIME OF THE MOTOR (SUBJECT TO PROPER USE), AND FOR ONE YEAR WITH RESPECT TO
COMPONENTS AND ACCESSORIES.

No Other Express or Implied Warranty Applies:

THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR EMERSON CEILING
FAN, AND ARE IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE,
WHETHER OR NOT THE PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE EMERSON CEILING FAN HAS BEEN SPECIFICALLY DESIGNED OR
MANUFACTURED FOR YOUR USE OR PURPOSE. EMERSON HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION,
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR COMPONENTS AND ACCESSORIES AS OF THE EXPIRATION OF THE
ONE YEAR WARRANTY PERIOD FOR SUCH COMPONENTS AND ACCESSORIES. IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE FOR THE MOTOR PORTION OF THE EMERSON CEILING FAN ARE LIKEWISE DISCLAIMED BY EMERSON AT SUCH TIME THAT THE EXPECTED LIFETIME
OF THE EMERSON CEILING FAN UNDER NORMAL USAGE HAS BEEN REACHED.  EXCLUSIONS OR LIMITATIONS OF IMPLIED WARRANTIES MAY VARY FROM
STATE TO STATE AND PROVINCE TO PROVINCE SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.

What We Will Do To Correct Problems:

If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during
the expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or
workmanship, you must contact Emerson during the applicable warranty period. If the defect is covered by warranty, Emerson will repair or replace the defective
motor, component or other accessory at no charge to you. If repair of the motor, component or accessory is not practical or possible within a reasonable time and no
replacement Emerson Ceiling Fan can be provided, Emerson will refund to you the actual purchase price of your Emerson Ceiling Fan. We will ship the repaired or the
replacement Emerson Ceiling Fan to you at no charge, but you are responsible for all costs of removal and reinstallation of your Emerson Ceiling Fan.

How You Can Receive Warranty Service:

You must be the original retail purchaser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty. You can
return your Emerson Ceiling Fan to your place of purchase, or you can call Emerson Customer Service at 1-800-237-6511 to obtain a return authorization and service
identification tag. In order for us to confirm that your Emerson Ceiling Fan is still under warranty, please retain your receipt or other proof of purchase and have that
information readily available when returning your Emerson Ceiling Fan to your place of purchase, or upon calling Emerson Customer Service. If you call Emerson
Customer Service, prior to your call please be prepared to provide all model numbers shown on your Emerson Ceiling Fan. Once we have processed your return
authorization request, we will provide you with a postage paid return label which should be affixed to the Emerson Ceiling Fan package you ship to the address listed at
the end of this limited warranty. The return label will be sent to the mailing address you provide to us by phone. 

What Is Not Covered:

This limited warranty does not extend to and expressly excludes:

The glass globes and light bulbs of your Emerson Ceiling Fan, 

Loss or damage to the motor or any component or accessory caused by normal wear and tear, rather than due to defects in materials or workmanship,

Loss or damage resulting from conditions beyond our reasonable control, including without limitation, repairs not made at our factory or authorized service center,
use of parts or accessories not provided to you as part of this warranty by our factory or authorized service center, mishandling, unreasonable use, misuse, abuse,
modifications or other damage caused by you or a third party to your Emerson Ceiling Fan while not in our possession, 

Loss or damage resulting from improper installation, or other failure to comply with instructions in your Owner's Manual.

This limited warranty is deemed null and void upon the occurrence of either of the following events:

You cease to own the Emerson Ceiling Fan product, or

The Emerson Ceiling Fan is moved from its original point of installation.

This limited warranty is only valid within the 50 United States, the District of Columbia, and Canada. No other written or oral warranties apply, and no employee, agent,
dealer or other person is authorized to give any warranties on behalf of Air Comfort Products or Emerson Electric Co.

Limitation of Liability

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY. TO THE EXTENT PERMITTED BY
LAW, IN NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR CONSEQUENTIAL
DAMAGES, INCLUDING ANY ECONOMIC LOSS, WHETHER RESULTING FROM NONPERFORMANCE, USE, MISUSE OR INABILITY TO USE THE EMERSON CEILING
FAN OR FOR THE NEGLIGENCE OF EMERSON OR AN EMERSON AUTHORIZED DEALER. EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN
PERFORMANCE AND IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT,
NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL EMERSON'S OR ANY EMERSON AUTHORIZED AGENT'S LIABILITY TO YOU OR ANY
INDIVIDUAL USING THE EMERSON CEILING FAN EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE EMERSON CEILING FAN. The term "consequential
damages" shall include, but not be limited to, loss of anticipated profits, business interruption, loss of use or revenue, cost of capital or loss or damage to property or
equipment.

How State and Provincial Law Relates To The Warranty:

Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.

Emerson Air Comfort Ceiling Fan Limited Warranty

BP7483 ASHLAND CF717  12/19/13  9:59 AM  Page 23

Содержание ASHLAND CF717BS00

Страница 1: ... s Manual CF717BS00 Brushed Steel CF717SW00 Satin White Model Numbers CF717ORB00 Oil Rubbed Bronze Net Weight 18 8 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com BP7483 ASHLAND CF717 12 19 13 9 59 AM Page 1 ...

Страница 2: ...s fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could re...

Страница 3: ...1 3 10 9 11 HARDWARE CONTENTS A B C D E F L K J I H G PACKAGE CONTENTS NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding Part Description Quantity 1 Wire Connectors 12 ga 5 2 Clevis Pin 1 3 Hairpin Clip 1 4 8 32 x 8mm Washer Head Blade Screws 16 5 ...

Страница 4: ...cuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not su...

Страница 5: ...gure 1 3 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step SETSCREW CLEVIS PIN MOTOR COUPLING DOWNROD HAIRPIN CLIP HAIRPIN CLIP MOTOR COUPLING SETSCREW 2 CLEVIS PIN DOWNROD Figure 2 3 2 Separate untwist and u...

Страница 6: ...od to make sure the setscrews are firmly installed against the downrod Figure 3 NOTE The setscrew must be properly installed as described above or fan wobble could result GROMMET COUPLER COVER MOTOR HOUSING DOWNROD Figure 4 3 4 Make sure the grommet is properly installed in the motor coupler cover then slide the motor coupler cover on the downrod until it rests on the motor housing Be sure the mot...

Страница 7: ...n and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING HANGER BALL 6 TO 9 INCHES 1 2 INCH WHITE WIRE BLUE WIRE BLACK WIRE 3 7 The fan comes with bl...

Страница 8: ... reinstalling the previously removed six screws and lockwashers Figure 10 Figure 10 4 Installing Ceiling Cover on Fan Motor Housing For Close to the Ceiling Mounting REMOVE SCREWS 6 INSTALL GASKET 4 1 Remove and retain six screws and lockwashers from the top of the motor housing Figure 8A 4 2 Remove the paper backing off the rubber gasket supplied in parts bag to expose the adhesive Position the r...

Страница 9: ...hat the T slots in the hanger bracket are aligned with the outlet box screws NOTE The hanger bracket must be mounted flush with the ceiling in order for the ceiling cover to install properly If necessary use leveling washers not supplied between the outlet box and the hanger bracket HANGER BRACKET LOOSEN TWO SCREWS SUPPLIED WITH OUTLET BOX OUTLET BOX SLIDE THE HANGER BRACKET ONTO THE OUTLET BOX SC...

Страница 10: ...rews Figure 13 Hanger bracket must seat firmly against outlet box If the outlet box is recessed use leveling washers between the hanger bracket and the outlet box until the bracket is flush with the ceiling If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING HANGER BRACKET SECURELY TIGHTEN SCREWS Figure 13 BP7483 ASHLAND CF717 12 19 13 9 59 AM Page 10 ...

Страница 11: ...d possible shock or fire hazard WARNING 7 Hanging the Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor Housing 7 1 Carefully lift the fan assembly up to the hanger bracket Pass the hook on the hanger bracket Figure 15 through one of the screw holes not the slots in the ceiling cover Figure 15 The hook must pass from the inside of the ceiling cover to the outside Th...

Страница 12: ... to the supply black hot wire using wire connector supplied Figure 17 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box NOTE When wiring the ceiling fan for close to the ceiling mounting there will be no green grounding lead fro...

Страница 13: ...s in the bracket and turn the cover counterclockwise Figure 19 Be sure that the lockwashers are between the screw heads and the ceiling cover Install the other two screws and lockwashers tighten all screws securely 9 Installation of Ceiling Cover 9 1 Remove the left screw and lockwasher from each side of the hanger bracket Figure 18 and loosen the other two screws NOTE When installing the ceiling ...

Страница 14: ...L HEAD SCREWS 2 per blade flange assembly SWITCH CUP PLATE Figure 22 10 2 Mount the blade flanges to the fan blades using three 8 32 x 8mm washer head blade screws supplied per blade Figure 21 Repeat this procedure for remaining four fan blades and blade flanges BLADE FLANGE 5 8 32 x 8mm WASHER HEAD BLADE SCREW 3 per blade FAN BLADE 5 Figure 21 10 1 Remove and discard the five motor hub spacers to...

Страница 15: ... are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly MOTOR CONNECTOR LIGHT KIT ASSEMBLY CONNECTOR LIGHT KIT ASSEMBLY Figure 23 To avoid possible fire or shock do not pinch wires between the light kit assembly and the switch cup plate WARNING LIGHT KIT ASSEMBLY SOCKETS 3 60 WATT maximum CANDELABRA BASE BULBS 3...

Страница 16: ... hole of the glass shade NOTE Be sure that the fan switch chain does not make contact with the light bulbs If necessary reposition the light fitter to avoid the fan switch chain from touching the light bulbs Place the glass shade onto the light kit assembly threaded nipple Figure 27 SPEED CONTROL PULL CHAIN LIGHT SWITCH PULL CHAIN GLASS SHADE THREADED NIPPLE Figure 27 11 6 Pass the light pull chai...

Страница 17: ...of this ceiling fan 12 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box Check the operation of the light by gently pulling on the light switch pull chain Figure 30 Check the operation of the fan by gently pulling on the speed control switch pull chain Figure 30 The operation sequence is as follows 1st pull High 2nd pull Medium Your fan is shipped from...

Страница 18: ... Accessories The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance tha...

Страница 19: ... 4 Tighten screws securely are loose 3 Fan wobbles 1 Setscrews in motor coupling are loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Screws securing fan blades to 3 Check to be sure screws which attach the fan flywheel are loose blades to the motor are tight 4 ...

Страница 20: ...20 ETL Model No CF717 16 Repair Parts 5 4 2 3 1 15 14 18 17 16 7 6 21 10 25 24 23 22 21 16 20 18 17 19 15 14 9 19 11 12 13 8 24 22 24 23 BP7483 ASHLAND CF717 12 19 13 9 59 AM Page 20 ...

Страница 21: ...upler Cover 1 764483 BS 764483 ORB 764483 SW 6 Fan Blades set of 5 764489 DCWA 764489 DCWA 764489 SWMP 7 Fan Blade Flanges set of 5 764487 BS 764487 764487 SW 8 Harness Wiring 764492 764492 1 764492 9 Light Kit Assembly 1 764493 764493 1 764493 10 60 Watt Candelabra Bulbs 3 11 Glass Shade 1 764494 764494 OM 764494 OM 12 Bowl Cap 1 764495 BS 764495 ORB 764495 SW 13 Finial Nut 1 764496 BS 764496 ORB...

Страница 22: ...22 ETL Model No CF717 Notes BP7483 ASHLAND CF717 12 19 13 9 59 AM Page 22 ...

Страница 23: ...can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling ...

Страница 24: ...stern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74830000 Form No BP7483 Revision 131215 ETL Model No CF717 Printed in China 12 13 BP7483 ASHLAND CF717 12 19 13 9 59 AM Page 24 ...

Отзывы: