background image

7

ASCO NUMATICS™

Visit our website at ASCO.com or contact us at (800) 972-2726

SERIES 

617 

INSTALLATION

MANUAL

Fluids: 

 

 Air or neutral gas, filtered at 50 μm condensate-free, lubricated or unlubricated, class 5 according to ISO 8573-

1:2010 [7:4:4]

Minimum Required pressure: 

 

At least 15 psi above the maximum outlet pressure

Pressure range: 

 

0 – 50 psi, 0 – 100 psi, 0 – 150 psi

Fluid temperature: 

 

0 ºC to 60 ºC (32 ºF to 140 ºF)

Ambient temperature: 

 

0 ºC to 50 ºC (32 ºF to 122 ºF)

Setpoint:  

  PSI  Pressure  Ranges:

 

 

 

PA & PB (50 & 100 psi ranges): in digital steps of 0.01 psi

 

 

PC (150 psi range): in digital steps of 0.1 psi

  

Bar Pressure Ranges: 

 

 

All: in digital steps of 0.001 bar

 

 

Hysteresis:  

1.5% of span

Linearity: 

 

1.5% of span

Repeatability: 

 

1.5% of span

Minimum setpoint: 

 

0.5% of span with shut-off function

Minimum outlet pressure: 

 

1% of span

Failsafe behavior: 

 

Pressure on hold on loss of power, without control

Specifications

Ø Ports 

NPT or BSPP

Ø

Orifice DN (mm)

Flow

Cv Flow Factor (Kv  Nm

3

/h)

at 6 Bar (l/min - ANR)

1/4

4

0.50 (0.43)

470

3/8

8

1.39 (1.20)

1300

1/2

15

5.57 (4.80)

5200

Electrical Characteristics

Nominal Diameter 

DN (mm)

Voltage *

Max. Power 

(W)

Max. Current 

(mA)

Insulation 

Class

Degree of 

Protection

Electrical Connection

4 , 8, 15

24 VDC = ± 10%

3.8 W 

(< 1 W at 

pressure)

160

H

IP65

5-pin M12 connector (not supplied)

* Max. ripple: 10%

Technical Characteristics

Fluid Characteristics

Construction

Body:  

 

Aluminum

Internal parts:  

POM (polyacetal)

Seals:  

 

NBR (nitrile)

Key Values

IO-LINK

Protocol Version

Specification V1.1

Baudrate

COM3 (230.4 kBaud)

Minimum cycle time

0.5 ms

Process data

2 Byte IN, 2 Byte OUT

Port type

Class A

Содержание Asco Sentronic LP 617 Series

Страница 1: ...617 Series IO Link CLASS A with Display and Controls Installation Manual SentronicLP IO Link CLASS A 617 Series ...

Страница 2: ...l Directive 2006 42 EC Handling assembly and putting into service and all settings and adjustments must be done by qualified authorised personnel only CAUTION Dangerous operating conditions may occur when using the programming interface on the valve as the valve may possibly not react to the analog setpoint any more Provide for protection against uncontrolled movement of equipment when putting the ...

Страница 3: ...s the output pressure The output pressure is adjusted in real time The control parameters can be changed with the additional DaS software The variability of the parameters used by the valve is ensured by the DaS software This flexibility makes it possible to adapt the valve to a very wide range of applications and to optimize the response time and the precision of the valve and prevent it from ove...

Страница 4: ...ing the arrow keys the output pressure can be changed left arrow key or arrow pointing down reduce the output pressure right arrow key or arrow pointing up increase the output pressure This operating mode can be exited by pressing both arrow keys at the same time or by briefly cutting off the supply voltage Operating Modes Shutoff If the setpoint is set to less than 0 5 the air will be released fr...

Страница 5: ...Manifold ships with required hardware and gaskets for connecting manifolds together M12 Class A B Compatible Cables and Accessories M12 90 5 Pin Female to Male Double Ended Cable Unshielded TD0505MIETA0571P 5 Meter TD0510MIETA0571P 10 Meter M12 90 5 Pin Female Single Ended Cable Unshielded TD0505MIE000071P 5 Meter TD0510MIE000071P 10 Meter M12 Straight 5 Pin Female to Male Double Ended Cable Unshi...

Страница 6: ...he DaS software To do this in the section Setpoint setting switch to Customer The adjustment range for the pressure is 10 to 200 WARNING Output pressures greater than the PMR Pressure Maximum Range will not be regulated by the valve i e the maximum output pressure is limited to the PMR In order to prevent damage to the sensor the supply pressure should always be less than the maximum input pressur...

Страница 7: ...ch screw connection must be lined with a fitting plastic sealing ring Teflon sealing tape and hemp may not be used because some of these materials may end up inside the valve A suitable silencer is to be used at port 3 Depending on the type of silencer used the time required for the air to be released may be extended The cross section of the pneumatic lines must be adjusted to the nominal diameter...

Страница 8: ... of span Repeatability 1 5 of span Minimum setpoint 0 5 of span with shut off function Minimum outlet pressure 1 of span Failsafe behavior Pressure on hold on loss of power without control Specifications Ø Ports NPT or BSPP Ø Orifice DN mm Flow Cv Flow Factor Kv Nm3 h at 6 Bar l min ANR 1 4 4 0 50 0 43 470 3 8 8 1 39 1 20 1300 1 2 15 5 57 4 80 5200 Electrical Characteristics Nominal Diameter DN mm...

Страница 9: ... value signal is sent to the valve if a target value setting is sent to the valve without the valve being under pressure this will result in unacceptable excessive heating of the valve 6 The device is calibrated with factory settings 7 The device must be sent to the factory if repairs are needed Safety Instructions These products must only be used in industrial compressed air systems These product...

Страница 10: ...52 8 25 45 43 Ø4 2 2x 65 5 17 15 20 12 40 M4 hole for earth screw 23 20 1 4 3x Programming interface 35 4 115 05 40 72 75 M4 2x 72 7 M4 hole for earth screw 29 8 6 65 5 17 15 78 5 25 24 10 25 40 Ø 6mm 3x M4 2x 34 8 M12 connector Programming interface DN 4 Subbase version Weight 0 49kg 1 08lbs DN 4 Inline version Weight 0 49kg 1 08lbs Dimensions mm ...

Страница 11: ...8 57 5 89 25 48 5 56 5 Ø 4 2 2x 3 8 3x Programming interface M4 hole for earth screw DN 8 Weight 0 93kg 2 05lbs 23 15 28 8 43 8 44 8 58 8 M4x8 10 2x 25 24 23 35 8 25 8 24 25 8 21 1 4 5 M6 3x 6 3 79 1 14 2 10 5 KM4 DIN 74T1 2x 60 8 43 40 90 36 8 Ø6 3x M6 2x 3 8 4x 32 9 4 0 5 18 DIN Rail mount EN 50022 35x7 5 DN 4 Joinable subbase Weight 0 3kg 0 66lbs Dimensions mm ...

Страница 12: ...SCO com or contact us at 800 972 2726 SERIES 617 INSTALLATION MANUAL 32 30 5 15 50 30 5 17 15 65 5 61 69 101 75 143 7 92 58 30 66 57 5 46 Ø 4 2 2x Programming interface M4 hole for earth screw 1 2 3x DN 15 Weight 1 33kg 2 93lbs Dimensions mm ...

Страница 13: ...pain 34 942 87 6100 United Kingdom 44 1695 713600 France 33 2 37 24 42 24 Germany 49 7237 9960 India 91 44 39197300 Italy 39 02 356931 Japan 81 798 65 6361 Mexico 52 55 5809 5640 Australia 61 2 9 451 7077 Brazil 55 11 4208 1700 Canada 1 519 758 2700 China 86 21 3395 0000 Czech Republic 420 235 090 061 Dubai UAE 971 4 811 8200 Global Contacts 2 19 ...