NOTICE
The information in this manual is subject to change without notice.
In no event shall ASCO NUMATICS be liable for technical or editorial errors or omissions. Neither is any liability assumed for accidental
or consequential damages arising out of or in connection with the supply or use of the information contained herein.
THIS MANUAL CONTAINS INFORMATION PROTECTED BY COPYRIGHT. NO PART OF THIS DOCUMENT MAY BE PHOTOCOPIED
OR REPRODUCED IN ANY FORM OR MANNER WHATSOEVER WITHOUT PRIOR WRITTEN PERMISSION FROM ASCO NUMATICS.
COPYRIGHT © 2016 - ASCO NUMATICS - All rights reserved.
This product complies with the essential requirements of the EMC Directive 2014/30/EU and its amendments. It is CE-approved.
A separate Declaration of Conformity is available on request.
Please provide ordering code and serial numbers of products concerned.
We herewith declare that the version of the product described in this installation manual is intended to be incorporated into or assembled
with other machinery and that it must not be put into service until the machinery into which it is to be incorporated has been declared in
conformity with the provisions of Council Directive 2006/42/EC.
Handling, assembly and putting into service and all settings and adjustments must be done by qualifi ed, authorised personnel only.
CAUTION!
Dangerous operating conditions may occur when using the programming interface on the valve as the valve may
possibly not react to the analog setpoint any more.
Provide for protection against uncontrolled movement of equipment when putting the valve into operation and before making
any modifi cations to the valve settings.
E S D
This product contains electronic components sensitive to electrostatic
discharge. An electrostatic discharge generated by a person or object
coming in contact with the electrical components can damage or
destroy the product.
To avoid the risk of electrostatic discharge, please observe the handling
precautions and recommendations contained in standard EN 100015-1.
Do not connect or disconnect the device while it is energised.
C A U T I O N
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC SENSITIVE
DEVICES
Table of Contents
Description 2
How To Order
2
Operating Elements
3
Manual Pressure Adjustment
3
Operating Modes
3
Electrical Connection
4
Analog Target Value - Output Pressure
5
Pneumatic Connection
6
Information on the Factory Settings
6
Technical Characteristics
7
Fluid Characteristics
7
Key Values
7
Care and Maintenance
8
Dimensions and Weights
9
Sentronic
LP
!