![Emerson 2202 Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/emerson/2202/2202_advanced-users-manual_101992059.webp)
Menu 3
Commander SK Advanced User Guide
59
Issue Number: 9 www.controltechniques.com
0
: OFF Hard frequency reference disabled
1
: On Hard frequency reference enabled
The hard frequency reference is a reference value which does not pass through the ramp system (Menu 2). It is added to the normal post ramp
frequency reference. The hard frequency reference is selected when Pr
3.23
= On(1).
Large changes in value may cause the drive to trip OI.AC.
Indicates the current value of the position counter.
3.19 to 3.21
Unused parameters
3.22
Hard frequency reference
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
Range
±
550 Hz
Default
0.0
Update rate
128 ms
3.23
Hard frequency reference selector
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Default
OFF(0)
Update rate
5 ms
3.24 to 3.28
Unused parameters
3.29
Position
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
1
1
Range
0 to 9999
Update rate
Background
3.30 to 3.31
Unused parameters
3.32
Position counter reset
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Default
OFF(0)
Update rate
Background
3.33
Position scaling numerator
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
3
1
1
1
Range
0.000 to 1.000
Default
1.000
Update rate
Background
NOTE