Menu 15
I/O options
184
Commander SK Advanced User Guide
www.controltechniques.com Issue Number: 9
This parameter shows the percentage of the encoder reference level being used.
The encoder reference is scaled by this parameter, before being sent to the encoder reference destination.
This parameter may be routed to any non-protected drive parameter.
After a modification to this parameter, the destination is only changed when a reset is performed.
Setting this Bit parameter to On will reset the drive encoder revolution counter (Pr
15.53
) and drive encoder position (Pr
15.54
) to zero.
Please refer to the SM-I/O Lite/ SM-I/O Timer user guide for further information on the SM-I/O Lite and SM-I/O Timer.
15.57
Drive encoder reference level
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
1
Range
-100% to +100%
Update rate
Background write
15.58
Drive encoder reference scaling
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
3
1
1
1
Range
0.000 to 4.000
Default
1.000
Update rate
Background read
15.59
Drive encoder reference destination
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
2
1
1
1
1
Range
Pr
0.00
to Pr
21.51
Default
Pr
0.00
Update rate
Drive read on reset
15.60
Encoder reset
Coding
Bit
SP
FI
DE Txt VM DP ND RA NC NV
PT
US RW BU PS
1
1
Range
OFF(0) or On(1)
Default
OFF(0)
Update rate
Encoder only: 13ms
All I/O routed: 30ms
NOTE
Содержание 2202
Страница 199: ......