INSTALLATION 

REMOVE OLD THERMOSTAT

1.  Shut off electricity at the main fuse box until installation is 

complete. Ensure that electrical power is disconnected.

2.  Remove the front cover of the old thermostat. 

With wires 

still  attached

,  remove  wall  plate  from  the  wall.  If  the 

old  thermostat  has  a  wall  mounting  plate,  remove  the 
thermostat and the wall mounting plate as an assembly.

3. 

Identify each wire attached to the old thermostat using 
the labels enclosed with the new thermostat.

4.  Disconnect the wires from old thermostat one at a time. 

DO 

NOT LET WIRES FALL BACK INTO THE WALL.

5.  Install new thermostat using the following procedures.

ATTENTION!

This product does not contain mercury. However, this product 
may replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do 
not touch any spilled mercury. Wearing nonabsorbent gloves, 
take up the spilled mercury and place into a container which 
can be sealed. If a cell becomes damaged, the unit should be 
discarded.
Mercury must not be discarded in household trash. When the 
unit  this  product  is  replacing  is  to  be  discarded,  place  in  a 
suitable container. Refer to www.white-rodgers.com for location 
to send the product containing mercury.

ATTACH THERMOSTAT BASE TO WALL

1.  Remove the packing material from the thermostat. Gently 

pull the cover straight off the base. Forcing or prying on the 
thermostat will cause damage to the unit.

2.  Place  base  over  hole  in  wall  and  mark  mounting  hole 

locations on wall using base as a template (see Fig.1).

3.  Move base out of the way. Drill mounting holes.
4.  Push wires through opening in thermostat base.
5.  Fasten  base  loosely  to  wall  using  two  mounting  screws. 

Place  a  level  against  bottom  of  base,  adjust  until  level, 
and then tighten screws. (Leveling is for appearance only 
and will not affect thermostat operation.) If you are using 
existing mounting holes, or if holes drilled are too large and 
do not allow you to tighten base snugly, use plastic screw 
anchors to secure subbase.

6.  Connect  wires  to  terminals  on  base  using  appropriate 

wiring schematic (see figs. 2 through 4).

7.  Push excess wire into wall and plug hole with a fire-resistant 

material  (such  as  fiberglass  insulation)  to  prevent  drafts 
from affecting thermostat operation.

O/B TERMINAL SWITCH SELECTION

The  O/B  switch  on  this  thermostat  is  factory  set  to  the  “O” 
position.  This  will  accommodate  the  majority  of  heat  pump 
applications,  which  require  the  changeover  relay  to  be 
energized in COOL. If the thermostat you are replacing or the 
heat pump being installed with this thermostat requires a “B” 
terminal, to energize the changeover relay in HEAT, the O/B 
switch must be moved to the “B” position.

Mounting

Hole

Mounting

Hole

Opening

for wires

Gas/Elec

Switch

Battery

Door

O/B

Switch

Figure 1. Thermostat Base

GAS / ELEC SWITCH

If your system is a heat pump, the GAS/ELEC Switch must be 
set to ELEC (see Fig. 1) If your system is a single stage, the 
switch must be set to GAS. The switch setting must agree with 
the system configuration selected in the configuration menu.

BATTERY LOCATION

“AA” Alkaline Batteries

Two “AA” alkaline batteries are installed in your thermostat with 
a  battery  tag  to  prevent  power  drainage.  Prior  to  use,  open 
the  battery  door  and  remove  the  battery  tag.  To  open,  pull 
the battery door as shown by the arrow and lift open. The two 
“AA” batteries will operate all functions or maintain time and 
continuously display the temperature during a loss of AC power. 
To replace batteries, pull the battery door shown by the arrow 
and  lift  open.  Using  the  polarity  indicated  inside  the  battery 
door, insert the batteries. To close the battery door, swing the 
door  down  while  pulling  in  the  direction  of  arrow.  Once  fully 
down, snap the door back into position.
Thermostat can be powered by system AC power or Battery. If 

 is displayed, the thermostat is battery powered. If 

 is not 

displayed, thermostat is system powered with optional battery 
back-up. When battery power remaining is approximately half, 
the 

 will be displayed. When 

“Change 

” is displayed, 

install fresh “AA” alkaline batteries immediately. For best results, 
use new premium brand alkaline batteries such as Duracell

®

 or 

Energizer

®

. We recommend replacing batteries every 2 years. 

If the home is going to be unoccupied for an extended period 
(over 3 months) and 

 is displayed, the batteries should be 

replaced before leaving. When less than two months of battery 
life remain, the setpoint temperature will offset by 10 degrees 
(10 degrees cooler in Heat mode / 10 degrees warmer in Cool 
mode). If offset occurs, the normal setpoint can be manually 
reset  with 

  or 

.  Another  offset  will  occur  within  two 

days if batteries are not replaced. To replace the batteries, set 
system to OFF.

Содержание 1F86-0244

Страница 1: ...el Programming Choice 1F86 0244 Non Programmable SPECIFICATIONS Electrical Rating Battery Power mV to 30 VAC 50 60 Hz or DC Input Hardwire 20 to 30 VAC Terminal Load 1 0 A per terminal 1 5A maximum all terminals combined Setpoint Range 45 to 90 F 7 to 32 C Differential Single Stage Heat 0 6 F Cool 1 2 F adjustable Differential Heat Pump Heat 1 2 F Cool 1 2 F adjustable Operating Ambient 32 to 105 ...

Страница 2: ...on O B TERMINAL SWITCH SELECTION The O B switch on this thermostat is factory set to the O position This will accommodate the majority of heat pump applications which require the changeover relay to be energized in COOL If the thermostat you are replacing or the heat pump being installed with this thermostat requires a B terminal to energize the changeover relay in HEAT the O B switch must be move...

Страница 3: ...rcuits are in only one of the systems remove the transformer of the system with NO safety circuits NOTE Optional Jumper for Single Stage Heat Pump R C G W Figure 4 Typical wiring diagram for two transformer single stage systems with safety circuits in BOTH systems Changeover Relay Y O B Compressor Contactor Changeover Relay is energized in COOL when O B switch is in the O position Changeover Relay...

Страница 4: ...isplays current temperature Figure 5 Thermostat display buttons and switches SYSTEM 2 1 3 4 5 6 7 8 9 11 10 9 Service indicatesadiagnosticfaultintheheating cooling system It does not indicate a fault in the thermostat 10 Change Filter is displayed when the system has run for the programmed filter time period as a reminder to change or clean your air filter 11 indicates power level of batteries Cha...

Страница 5: ...gle Stage Heat is Medium Cycle ME For Single Stage Cool the default setting is fast FA To change cycle rate press the and buttons The cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL SS Heat 0 6 F 0 8 F 1 2 F SS Cool 1 2 F 1 7 F 5 Select Compressor Lockout CL OFF or ON Selecting CL On will cause the thermostat to wait 5 minutes between cooling cycles This is inten...

Страница 6: ...ate 3 Press to adjust temperature setting below room temperature The heating system should stop operating To prevent compressor and or property damage if the outdoor temperature is below 50o F DO NOT operate the cooling system CAUTION Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes...

Страница 7: ... to thermostat or system 3 Cooling System requires service or thermostat requires replacement Set System Switch to Cool and lower setpoint below room temperature Verify thermostat and system wires are securely at tached Same procedures as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature There may be up to a five minute delay befor...

Страница 8: ...www white rodgers com White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 ...

Страница 9: ...ite rodgers com White Rodgers es una división de Emerson Electric Co El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co Línea de ayuda para el usuario 1 800 284 2925 ...

Страница 10: ...calefacción esté funcionando correctamente El sistema no enfría 1 El interruptor System no está ajustado en Cool 2 La conexión al termostato o al sistema está suelta 3 El sistema de enfriamiento requiere servicio técnico o debe cambiarse el termostato Ajuste el interruptor System en Cool y baje la temperatura de referencia por debajo de la temperatura ambiente Verifique que los cables del termosta...

Страница 11: ...e la temperatura por debajo de la temperatura ambiente El sistema de calefacción debería dejar de funcionar Para evitar daños al compresor y o daños materiales si la temperatura externa está por debajo de los 50 F NO utilice el sistema de enfriamiento PRECAUCIÓN No deje que el compresor funcione a menos que los calentadores de aceite del compresor hayan estado en funcionamiento durante 6 horas y q...

Страница 12: ... FA Para cambiar la velocidad del ciclo presione el botón y el botón Las velocidades de los ciclos son las indicadas a continua c ión según la opción elegida MODO Rápido Medio Lento FA ME SL SS Heat 0 6 F 0 8 F 1 2 F SS Cool 1 2 F 1 7 F 5 Selección de bloqueo del compresor CL en OFF u ON Si se selecciona CL On el termostato esperará 5 minutos entre ciclos de enfriamiento para evitar que el compres...

Страница 13: ...talla botones e interruptores del termostato SYSTEM 2 1 3 4 5 6 7 8 9 11 10 8 Muestra la temperatura actual 9 Service servicio indica una falla en el sistema de calefacción enfriamiento No indica una falla del termostato 10 Change Filter cambiar filtro aparece cuando el sistema se ha utilizado por la cantidad de tiempo seleccionada en el filtro para recordarle que debe cambiar o limpiar el filtro ...

Страница 14: ... en uno de los sistemas retire el transformador del sistema SIN circuitos de seguridad NOTA Puente opcional para bomba de calor de una sola etapa R C G W Y O B 24 VCA 120 VCA VIVO NEUTRO VIVO NEUTRO NEUTRO NEUTRO Figura 4 Diagrama de conexiones típico para sistemas de una sola etapa de dos transformadores con circuitos de seguridad en AMBOS sistemas Relé de conmutación Contactor del compresor Relé...

Страница 15: ...tato viene ajustado de fábrica en la posición O Esta opción admite la mayoría de las aplicaciones de bomba de calor que requieren que el relé de conmutación esté energizado en COOL Si el termostato que está cambiando o la bomba de calor que está instalando con este termostato requiere una terminal B para energizar el relé de conmutación en HEAT el interruptor O B debe colocarse en la posición B Or...

Страница 16: ...e programación 1F86 0244 No Programable ESPECIFICACIONES Características eléctricas Alimentación con pilas mV a 30 VCA 50 60 Hz o CC Entrada Cableado interno 20 a 30 VCA Carga en terminales 1 0 A por terminal 1 5 A máx en todas las terminales combinadas Rango de temperatura de referencia 45 a 90 F 7 a 32 C Diferencial una sola etapa Calor 0 6 F frío 1 2 F ajustable Diferencial bomba de calor Calor...

Отзывы: