SI-I/O User Guide
31
Issue Number: 3
Figure 8-4 Analog input 1/2, differential analog input
mm.ppp
mm.ppp
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown in their default settings
??.???
??.???
x(-1)
Differential Analog
input destination
Differential Analog
input invert
Differential Analog
input offset
Differential
Analog input
scaling
Differential
Analog input
Differential
Analog input
maximum
Differential
Analog input
minimum
S.03.046
S.01.015
S.03.041
S.03.043
S.03.045
S.03.044
Differential
analog input
destination
Any unprotected
variable parameter
S.01.016
S.03.004
T7 Digital input 5,
Analog input 1 mode
T8 Digital input 6,
Analog input 2 mode
+
+
+
-
2
2
T7
T8
A/D
S.03.042
??.???
??.???
x(-1)
T7 Analog
input 1 destination
T7 Analog
input 1 invert
T7 Analog
input 1 offset
T7 Analog
input 1
scaling
T7 Analog
input 1
T7 Analog input
1 maximum
T7 Analog input
1 minimum
S.03.016
S.03.011
S.03.013
S.03.015
S.03.014
Analog input 1
destination
Any unprotected
variable parameter
S.03.001
T7 Digital input 5,
Analog input 1 mode
+
+
1
S.01.015
T7
A/D
S.03.012
??.???
??.???
x(-1)
T8 Analog input
2 destination
T8 Analog
input 2 invert
T8 Analog
input 2 offset
T8 Analog
input 2
scaling
T8 Analog
input 2
T8 Analog input
2 maximum
T8 Analog input
2 minimum
S.03.026
S.03.021
S.03.023
S.03.025
S.03.024
Analog input 2
destination
Any unprotected
variable parameter
S.03.002
T8 Digital input 6,
Analog input 2 mode
+
+
1
S.01.016
T8
A/D
S.03.022
Содержание 0478-0047-03