SI-I/O User Guide
11
Issue Number: 3
6 Single line descriptions
6.1
Single line descriptions
6.1.1
Menu 0 - Setup
6.1.2
Menu 1 - I/O Setup
Parameter
Range (
Ú
)
Default (
Ö
)
Type
MM.001
Module ID
0 to 999
209
RO
Num ND NC PT
MM.002
Software Version
00.00.00.00 to 99.99.99.99
RO
Num ND NC PT
MM.003
Hardware Version
00.00 to 99.99
RO
Num ND NC PT
MM.004
Serial Number LS
0 to 99999999
RO
Num ND NC PT
MM.005
Serial Number MS
0 to 99999999
RO
Num ND NC PT
MM.006
Module status
Initializing (0), OK (1), Config (2), Error (3)
RO
Num ND NC PT
MM.007
Module reset
Off (0) or On (1)
Off (0)
RW
Bit
NC
MM.008
Module default
Off (0) or On (1)
Off (0)
RW
Bit
NC
MM.030
Slot Indicator
0 to 8
RO
Num ND NC PT
MM.031
Slot Menu Number
0 to 255
RO
Num ND NC PT
Parameter
Range (
Ú
)
Default (
Ö
)
Type
S.01.001
Reset I/O Interface
Off (0) or On (1)
Off (0)
RW
Bit
NC
S.01.002
Default I/O Interface
Off (0) or On (1)
Off (0)
RW
Bit
NC
S.01.004
Option Module Status
Initializing (0), OK (1), Config (2), Error (3)
RO
Txt
ND
NC PT
S.01.005
I/O Output Enable
Register
0000000000 to 1111111111
0000000000
RW
Bin
US
S.01.006
I/O Input Register
00000000 to 11111111
RO
Bin
US
S.01.007
I/O Output Register
0000000000 to 1111111111
0000000000
RW
Bin
US
S.01.008
Digital I/O Logic Polarity
Negative Logic (0) or Positive Logic (1)
Positive Logic (1)
RW
Txt
US
S.01.009
Open Collector Output
Push-Pull (0) or Open Collector (1)
Push-Pull (0)
RW
Txt
US
S.01.010
I/O Read Word
0000000000 to 1111111111
0000000000
RO
Bin
S.01.011
T2 Digital I/O 1 Mode
Digital Input (0) or Digital Output (1)
Digital Input (0)
RW
Txt
US
S.01.012
T3 Digital I/O 2 Mode
Digital Input (0) or Digital Output (1)
Digital Input (0)
RW
Txt
US
S.01.013
T4 Digital I/O 3 Mode
Digital Input (0) or Digital Output (1)
Digital Input (0)
RW
Txt
US
S.01.014
T5 Digital I/O 4 Mode
Digital Input (0) or Digital Output (1)
Digital Input (0)
RW
Txt
US
S.01.015
T7 Digital Input 5 /
Analog Input 1 Mode
Digital Input (0) or Volt IN (1)
Volt IN (1)
RW
Txt
US
S.01.016
T8 Digital Input 6 /
Analog Input 2 Mode
Digital Input (0) or Volt IN (1)
Volt IN (1)
RW
Txt
US
S.01.017
T9 Digital Input 7 /
Analog Input 3 Mode
Digital Input (0), Volt IN (1), 4-20mA Low (2), 20-
4mA Low (3), 4-20mA Hold (4), 20-4mA Hold (5),
0-20mA (6), 20-0mA (7), 4-20mA Trip (8), 20-
4mA Trip (9), 4-20mA (10), 4-20mA (11)
Volt IN (1)
RW
Txt
US
S.01.018
T11 Digital Input 8 /
Analog Output 1 Mode
Digital Input (0), Volt Out (1), 4-20mA (2), 20-
4mA (3), 0-20mA (4), 20-0mA (5),
Volt Out (1)
RW
Txt
US