OUTDOOR UNIT INSTALLATION
CAUTION
♦
♦
♦
♦
Set the unit on a strong stand, such as on made of concrete blocks.
♦
When the unit is exposed to vibration, install protective rubber pieces under it.
♦
Do not install the unit directly on the ground, because it will cause trouble.
♦
Install the unit where it will not be tilted by more than 5
o
(1) When the outdoor unit will be exposed to strong wind, fasten it with bolts at the places indicated by the
arrow
(2) Since the drain water flows out of the outdoor unit during heating operation, install the drain pipe and
connect it to a commercial 16 mm hose. (Heat pump model only)
(3) When installing the drain pipe, plug another hole in the bottom of the outdoor unit with drain cap so there
is no water leakage.
CONNECTING THE PIPING
FLARE PROCESSING
(1) Cut the connection pipe with pipe cutters so that the pipe is not deformed.
(2) Holding the pipe downward so that cutting can not enter the pipe, remove the burrs.
(3) Remove the flare nut from the indoor unit pipe and outdoor unit, insert the flare nut onto the pipe and flare with
flaring tool.
(4) Check if the flare part "L" is spread uniformly and that there are no cracks.