16.7 Alarms Management.
Use this function to enable/disable the relay output for level alarm (lev) and/or
standby (stby) and/or flow sensor (sefl) and/or ppm and/or percentage (PERC)
and/or MLQ and/or Batch.
If alarm is activated for one or more events then the output relay will be enabled,
the pump will show the alarm status and it’ll stop or not the dosing activity.
If alarm is not activated for one or more events then the output relay will
be disabled, the pump will show the alarm status and it’ll stop or not the
dosing activity.
- Use
“UP”
key to choose the alarm to set.
-Use
“RIGHT”
key to enable (EN) or disable (DI) the alarm.
-Press
“E”
key to save data and
“ESC”
to exit to
main menu. Otherwise press
“ESC”
to discard data
and exit to main menu.
SET [06]
aLARMS
ALARM[1]
LEV EN
Key
ALARM[2]
stby EN
Key
Key
E