3
3-34
EMC Fibre Channel with QLogic HBAs in Windows Hosts
Configuring an EMC Boot Device
How a Server Responds to Failure in the Boot LUN Path
Failure in the path to a SAN-based boot LUN can halt Windows in a
fatal error condition. Depending on the failure, Windows may be able
to transfer control to another path and continue.
Table 3-1 shows server reactions to failures in different components.
a. Depending on the fabric configuration, if multiple switches are used, then this behavior would
qualify under the Multipath category.
b. CLARiiON only.
Explanations of Entries
◆
STOP Error
(fatal blue screen) — Indicates host failure and
chance of data corruption.
◆
No boot
— Cannot boot Windows.
◆
Halt
— Windows cannot recover before system has completed
startup. (You must reboot and follow the power-up scenario.)
◆
Manual
— Manual intervention is required to continue.
(Typically, initiate a LUN trespass using CLI or Manager. With
Manager, enable LUN Auto-Assignment in LUN properties.)
◆
Multipath
or
Trespass
— This automatic operation allows no
disruption of service. (The delay caused by this operation may
affect Windows stability.)
Table 3-1
Server Response to Failure in the Boot LUN Path (Single Fault)
Configuration
Server State
HBA Failure
Switch Failure
Boot
SP/Director
Port Failure
Boot
SP/Director
Failure
Catastrophic
Storage
System Failure
2 or more HBAs,
failover software
Windows running
Multipath
STOP error
a
Multipath
Trespass
b
STOP error
Windows booting
Halt
Halt
Halt
Halt
Halt
Power up
Multipath
No Boot
a
Multipath
Manual
No Boot
1 HBA, failover
software
Windows running
STOP error
STOP error
Trespass
Trespass
b
STOP error
Windows booting
Halt
Halt
Halt
Halt
Halt
Power up
No boot
No boot
Manual
Manual
No boot
1 HBA, no
failover software
Windows running
STOP error
STOP error
STOP error
STOP error
STOP error
Windows booting
Halt
Halt
Halt
Halt
Halt
Power up
No boot
No boot
No boot
No boot
No boot
Содержание Qlogic QLA22 Series
Страница 6: ...EMC Fibre Channel with QLogic HBAs in Windows Hosts vi Contents...
Страница 32: ...2 2 20 EMC Fibre Channel with QLogic HBAs in Windows Hosts Installing and Configuring the HBA Driver...
Страница 68: ...3 3 36 EMC Fibre Channel with QLogic HBAs in Windows Hosts Configuring an EMC Boot Device...
Страница 72: ...A A 4 EMC Fibre Channel with QLogic HBAs in Windows Hosts Third Party Software...
Страница 76: ...B B 4 EMC Fibre Channel with QLogic HBAs in Windows Hosts Troubleshooting...