General Installation Recommendations

Installation

IND100210-19

General mounting instructions

1. 

 

The useful life of the components of all Electronics Units generally decreases with increasing ambient

 

temperature; it is therefore advisable to install such units in air-conditioned rooms. If there are no such

 

facilities, these rooms must at least be dry, adequately ventilated and kept at a suitable temperature in order

 

to prevent the formation of condensation inside the unit.

2. 

 

With most Electronic Units, cooling takes place via the surface of the casing. The cooling must not be

 

impaired by partial covering of the unit or by installation of the unit in a confined cabinet.

3. 

 

In the area of the wheel house, the distance of each electronics unit from the magnetic standard compass or

 

the magnetic steering compass must not be less than the permitted magnetic protection distance. This

 

distance is measured from the centre of the magnetic system of the compass to the nearest point on the

 

corresponding unit concerned. The exact distance is often mentioned in the specific product specifications.

4.

  

Transportation damage, even if apparently insignificant at first glance, must immediately be examined and be

 

reported to the freight carrier. The moment of setting-to-work of the equipment is too late, not only for

 

reporting the  damage but also for the supply of replacements.

5.

  

The classification is only valid for approved mounting brackets provided by Hatteland Technology. The unit

 

shall be mounted stand-alone without any devices or loose parts placed at or nearby the unit. Any other type

 

of mounting might require test and re-classification.

6.   

Additional rules may apply to certain procedures where the symbols   and   are present. For more

 

information, review “IEC62368 policy for Hatteland Technology product” section later in this manual.

Cables

Use only high quality shielded signal cables. For RGB/DVI cables use only cables with separate coax for Red, Green 

and Blue.

Содержание Hatteland HT20 70 Series

Страница 1: ...ANUAL 4 Bay Model 2 Bay Model HT20370 ww xx yzzzzzz HT20470 ww xx yzzzzzz where ww CPU type i3 i5 i7 xx Power Input AC DC y manufacturing site zz configuration HT20x70 Compact Fanless Marine Computer...

Страница 2: ...righted to the respective owners The products may not be copied or duplicated in any way This documentation contains proprietary information that is not to be disclosed to persons outside the user s c...

Страница 3: ...al Block Connector Overview 20 Cabinet cover removal 23 Installing PCIe Card Rework PCI Bracket Options Notice 24 PCIe Card removal replacement Introduction 25 Mounting Brackets for Table Desktop Moun...

Страница 4: ...VSDDPVGA340 HT DPM2VGAF A1 62 DisplayPort to VGA adapter 62 Specifications RC3473 HT DPM2DVI DF A1 63 DisplayPort to DVI adapter 63 Specifications JH C01MF A A 64 Technical Drawings 65 Technical Draw...

Страница 5: ...ction 134 Pinout Assignments 136 Trouble shooting 139 Operating System Recovery tool 139 How to activate Windows Recovery Environment on OS Drive 143 IEC62368 policy for Hatteland Technology products...

Страница 6: ...d Note Only applicable for factory delivered units with DC Power Input HT 20370 BLZP 5 08 02 180F SN BK BX 3125194433 KGG MSTB 2 5 2 1803934 1 x 2 pin Terminal Block 5 08 for 24VDC Power 1 x 2 pin Cab...

Страница 7: ...RS 422 RS 485 NMEA 4 Channel PCA100828 1 4 x 5 pin Terminal Block 3 81 for Digital Input Output PCA100297 1 PNY NVIDIA Quadro P620 1 x Installation guide 1 x DVD with drivers support software 4 x mDP...

Страница 8: ...8 This page left intentionally blank...

Страница 9: ...9 General...

Страница 10: ...ble for use in locations where children are likely to be present Ordinary person Sailor End User Not allowed to open unit Not allowed to install the unit Not allowed to terminate connect cables to the...

Страница 11: ...formation to help you make an informed choice as to the right product for your needs You will find detailed product descriptions and specifications for the entire range on Displays Computers Panel Com...

Страница 12: ...ring or entertainment solutions Hatteland Technology can fulfil your high expectations at a reasonable cost Our computer range covers all eventualities and requirements We offer a wide range of proces...

Страница 13: ...t if OS was part of factory option order Linux OS does not have any label As per delivered from supplier Label applies for Windows 10 IoT Enterprise Type Quality Control QC Label Size 30mm wide x 23mm...

Страница 14: ...14 This page left intentionally blank...

Страница 15: ...15 Installation...

Страница 16: ...e must be provided 5 To further improve the cooling of the unit we recommend installing Cooling Fans underneath blowing upwards into the unit air inlet This may be required in high temperature applica...

Страница 17: ...his distance is measured from the centre of the magnetic system of the compass to the nearest point on the corresponding unit concerned The exact distance is often mentioned in the specific product sp...

Страница 18: ...d cord 3 A one megaohm resistor installed in the wrist connection end of the ground cord is a safety requirement 4 Hatteland Technology recommends to use an Static dissipative ESD work mat positioned...

Страница 19: ...located as close as possible to the connector piece that connects to the rear of computer When ready Open the ferrite place the cable inside as shown in FIG1 and then gently close it until a click can...

Страница 20: ...roximate actual Housing and Hood may deviate slightly but function remains the same 5 pin Cable Housing Illustration 2 pin Cable Housing Illustration 4 pin Cover Hood Illustration KGG MC 1 5 5 5 pin K...

Страница 21: ...lready be plugged into the unit as per factory installation FIG 2 Strip carefully the insulation from the cable to expose the wire s inside FIG 3 Ensure that the wire s is without any loose threads to...

Страница 22: ...Recommended Cable Thickness 2 pin DC Power Input Terminal Block 5 08 Minimum 20 AWG Maximum 18 AWG 4 pin CAN Terminal Block 3 81 Minimum 22 AWG Maximum 20 AWG 5 pin NMEA COM Terminal Block 3 81 Minim...

Страница 23: ...d in this section with arrows in RED color Please disconnect ALL cables from the computer unit before proceeding Procedure applies for all HT20x70 models 1 Unscrew 8 screws M3x5L S S from top of cabin...

Страница 24: ...ect ALL cables from the computer unit before proceeding 1 Identify if any PCI Bracket Options are present as indicated If yes proceeed to step 2 3 4 If no please proceed to next page in this manual 2...

Страница 25: ...r Please disconnect ALL cables from the computer unit before proceeding Procedure applies for all HT20x70 models 1 Unscrew 6 screws on each side and the middle of the top bracket and gently lift the b...

Страница 26: ...ge Please review specifications and Technical Drawings Accessories chapter in this user manual for additional information Procedure applies for all HT20x70 models Front view and Measurements Side View...

Страница 27: ...omes with cable tie hinges for securing cables further Please review specifications and Technical Drawings Accessories chapter in this user manual for additional information Procedure applies for all...

Страница 28: ...echnical Drawings Accessories chapter in this user manual for additional information Procedure applies for all HT20x70 models Front and top view and Measurements with 2U rack mount installed 1 Remove...

Страница 29: ...r to attaching Slide Rails Please review specific drawings in this user manual for suitable holes and measurements 3rd party mounting instructions found in the Sliding Rails package Procedure applies...

Страница 30: ...ow is not recommended by Hatteland Technology 1 On wall connectors facing up or down even with external fan pushing away heat Inside or outside of cabinet does not matter 2 On wall connectors facing l...

Страница 31: ...s removed from motherboard If Factory Default BIOS settings was changed after unit was received from factory please write down changes if known before doing this procedure Operating System installed w...

Страница 32: ...the battery will pop up automatically 2 1 2 5 Carefully grab the battery with finger nail and remove it from the holder 6 Place the NEW battery as aligned in the lower part first Viewed in opposite d...

Страница 33: ...g system may require additionally tasks to be performed before computer shuts down and turns off the unit To reset the computer in case of severe software failure press this button This reset button i...

Страница 34: ...ips PH2 Tightening torque 0 4Nm Repeat the procedure in reverse FIG3 2 1 to mount FIG 1 FIG 4 Optional Extra locking mechanism inside computer to prevent SSD s from being removed unintentionally or by...

Страница 35: ...2 RS 422 RS 485 4 x USB3 1 USB C Grounding Screw MIC and Speaker 4 x Network Audio AMP PCI Bracket options Connector area of computer DC Power Input model Grounding Screw Power Input DC 2 x DisplayPor...

Страница 36: ...2 x DisplayPort RS 232 RS 422 RS 485 4 x USB3 1 USB C MIC and Speaker 4 x Network Audio AMP Grounding Screw Connector area of computer DC Power Input model Expansion Module Area Grounding Screw PCIe x...

Страница 37: ...D SUB 9P connector male connectors Fasten the cable to the connector using the provided screws on the cable housing itself For configuration please review the Appendix chapter section BIOS On board C...

Страница 38: ...able operation only USB3 0 specific external compliant peripherals should be connected to these ports as some USB1 1 2 0 devices may not be fully compatible Local testing of USB1 1 2 0 equipment conne...

Страница 39: ...ght FH Half Length HL 2GB Graphics Card Connectors 4 x miniDP DisplayPort Female Typenumber PNY NVIDIA Quadro P620 PCIe x16 Intel Network Adapter 1GbE Connectors 2 x RJ 45 Typenumber I350T2V2BLK PCIe...

Страница 40: ...n dedicated bracket to house the Optional Module securely to the unit s outer chassis For technical specifications see separate datasheets in this manual for each factory mounted module Example illust...

Страница 41: ...ep a persistent configuration at our factory This is seen from user s Point of View at rear of the unit Priority List amongst module installed in Expansion Area 1 and 2 1 COMx2 A 2 NMEA COM B 3 CAN C...

Страница 42: ...nd Modules are listed The numbering are only applicable for COM Ports and not other ports such as network RJ 45 COM Port On board factory option Description 1 RS232 RS422 RS485 Onboard External connec...

Страница 43: ...43 Specifications...

Страница 44: ...Server 2016 2019 64bit Windows 10 IoT Enterprise 2019 LTSC 64bit Linux Kernel 4 1x or later version External Connector Type Computer Specifications HT RMK STD E1 2U Rack Mount Kit 19 HT20xxx HT 00262...

Страница 45: ...Channel where applicable available sizes are Single Channel 1x8GB 2400MHz Dual Channel 2x8GB 2400MHz 2x16GB 2400MHz 2x32GB 2666MHz Storage 2 5 SSD SATA 240GB 0 9PBW 480GB 1 2PBW 960GB 3 4PBW 1 9TB 7...

Страница 46: ...46 This page left intentionally blank...

Страница 47: ...47 Specifications Factory Options...

Страница 48: ...5 4th EN 60945 2002 IACS E10 DNV Det Norske Veritas GL Germanischer Lloyd LRS Lloyd s Register of Shipping ABS American Bureau of Shipping BV Bureau Veritas CCS China Classification Society KR Korean...

Страница 49: ...ermination resistor always see the full output voltage No ECHO x NOTE Required for some MODBUS Compability Jumper mounted This setting is only to be used during half duplex communication When this jum...

Страница 50: ...Device TX External Device RX RX Pin 1 TxD Z Pin 2 TxD Y Pin 5 RxD A Pin 4 RxD B 1 1 1 2 2 2 4 4 4 5 5 5 Note 120 termination on TX pins are rarely needed unless cable is long or enviroment is very no...

Страница 51: ...ion Black is always connected Blue is connected when the device acts as a receiver Red is connected when the device acts as a transmitter Total 5 wires Termination if unit is master 1 x 110 120 resist...

Страница 52: ...1 In 052 24VDC Pin 02 In 053 GND Ground Pin 03 In 061 24VDC Pin 04 In 062 Input 10 pin Digital Output Input Serial Module Mechanical Relay COM isolated RS 422 485 3 A XIG OUT SER I O 1 2 3 4 5 1 2 3 4...

Страница 53: ...X Panel Computers and selected Stand alone Computers The Hatteland Technology CAN Module support socketCAN driver in both Windows and Linux environment which allow the user to add their own functions...

Страница 54: ...urer i e in the normal case is there no requirements for low level software development This module will mainly be integrated electrical and mechanical in the final products such as Series X G1 G2 Pan...

Страница 55: ...ard tested type approved by the following classification societies IEC 60945 4th EN 60945 2002 IACS E10 EU RO MR Mutual Recognition ClassNK Nippon Kaiji Kyokai Safety IEC60950 The DIO module is intend...

Страница 56: ...es X G1 G2 Panel Computers and selected Stand alone Computers Please check datasheet for your unit if PCA100298 1 is listed as part of Factory Options Description Internal 2 x USB to 2 x RJ 45 Connect...

Страница 57: ...d is replaced most operating system will not change COM port number Outputs are short circuits protected 1 2 3 4 5 6 7 8 9 2 Ports available in Operating System as COMx A COMx B Pinout Assignments 67...

Страница 58: ...58 This page left intentionally blank...

Страница 59: ...59 Specifications Accessories...

Страница 60: ...dule version This provides flexibility for new installations and easy upgrade of already installed systems In fact any Hatteland Technology product that has a USB2 0 port can take advantage of these E...

Страница 61: ...7 8 11 55 X X X HT 00264 OPT A2 SLCAN 1 x CAN isolated Via 4 pin Terminal Block 3 81 Connector Connects through 1 x USB Cable Based on ZIA0001310 SLCAN https www hattelandtechnology com hubfs pdf ind_...

Страница 62: ...62 IND100129 239 Specifications VSDDPVGA340 HT DPM2VGAF A1 DisplayPort to VGA adapter...

Страница 63: ...63 IND100129 255 Specifications RC3473 HT DPM2DVI DF A1 DisplayPort to DVI adapter...

Страница 64: ...A ports to all Hatteland Technology computers and panel computers with standard USB Type A ports RoHS Compliant Description Specifications Waterproof Rate IP67 No Ingress of dust Protected against har...

Страница 65: ...65 Technical Drawings...

Страница 66: ...ology AS Any authorized reproduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Di...

Страница 67: ...ology AS Any authorized reproduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Di...

Страница 68: ...68 This page left intentionally blank...

Страница 69: ...69 Technical Drawings Accessories...

Страница 70: ...orized reproduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might be...

Страница 71: ...thorized reproduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might...

Страница 72: ...y authorized reproduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions mi...

Страница 73: ...n whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might be shown with or withou...

Страница 74: ...n whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might be shown with or withou...

Страница 75: ...roduction in whole or in part must include this legend Hatteland Technology AS Proprietary information Not to be distributed to any third party without written permission Dimensions might be shown wit...

Страница 76: ...76 This page left intentionally blank...

Страница 77: ...77 Appendixes...

Страница 78: ...st program which guarantee that SSD performance complies to defined parameters in the specifications and that the SSD will operate without issues in delivered system configuration hardware and softwar...

Страница 79: ...tional lifetime 2 Selection of SSD Select SSD type series Define minimum expected lifetime Year Define minimum required SSD capacity GB From datasheet check if the endurance is expressed as PBW TBW or...

Страница 80: ...imum lifetime with respect to wear out year Where x Data rate GB per year Where z Total amount of data written data to SSD during its whole lifetime Step by Step Calculation Step 1 Measure preferred o...

Страница 81: ...file button at home screen Measurement 1 Check and save time for start test scenario 2 Execute the test scenario long enough to cover all valid use cases which may affect disk activity Recommended mea...

Страница 82: ...82 Appendix IND100077 227 BIOS Overview and functions BQ370 MH3 BIOS Step Ver 0 1...

Страница 83: ...4 7 1 1 Smart FAN mode Configuration 20 4 8 Preheat Function Configuration 21 4 9 S5 RTC wake settings 22 4 10 Serial Port Console Redirection 23 4 11 Intel TXT information 24 4 12 USB Configuration 2...

Страница 84: ...3 BIOS 3 5 2 1 5 PCI Express Root Port 21 PCIe x4 Slot PCIEX4_1 40 5 2 2 SATA and RST Configuration 41 5 2 3 USB configuration 42 5 2 4 HD Audio Configuration 43 5 2 5 Serial IO Configuration 44 6 Sec...

Страница 85: ...can display a sub menu from this field A sub menu contains additional options for a field parameter To display a sub menu move the highlight to the field and press Enter The sub menu appears Use the...

Страница 86: ...you enter the BIOS the following screen appears The BIOS menu screen displays the items that allow you to make changes to the system configuration To access the menu items press the up down right lef...

Страница 87: ...verview of the general system specifications The BIOS automatically detects the items in this menu Use this menu for basic system configurations such as time date etc BIOS Information Displays the aut...

Страница 88: ...the screen such as Chipset configuration to go to the sub menu for that item You can display an Advanced BIOS Setup option by highlighting it using the Arrow keys All Advanced BIOS Setup options are d...

Страница 89: ...This depends on CPU sku Software Guard Extensions SGX software controlled Enable or disables Guard Extensions Configuration options Disabled Enabled Software Controlled Select owner EPOCH input type...

Страница 90: ...Configuration options Disabled Enabled Turbo mode Enabled Enable or disable Turbo mode Configuration options Enabled Disabled C status Enabled Enable or disable CPU Power Management Allows CPU to go...

Страница 91: ...Configuration It shows ME version and ME status ME State Enable Enable or Disable Intel ME Configuration options Enable Disable ME Unlock Control Lock ME unlock switch function This function will aut...

Страница 92: ...BQ370 MH3 BIOS BQ370 MH3 BIOS 11 4 3 Intel ICC ICC OD Watchdog Timer Disabled When enabled the ICC OC watchdog timer is exposed to OS as an ACPI device WDT HW is always used by BIOS when clock settin...

Страница 93: ...r Disable BIOS support for security device Configuration options Disable Enable SHA 1 PCR Bank Enabled Enable or Disable SHA 1 PCR Bank Configuration options Disabled Enabled SHA256 PCR Bank Enabled E...

Страница 94: ...sabled Enabled ACPI Sleep State S3 Suspend to RAM Select the highest ACPI sleep state the system will enter the SUSPEND button is press Configuration options Suspend Disabled S3 suspend to RAM S3 Vide...

Страница 95: ...Step 14 BQ370 MH3 BIOS 4 6 NCT6106D Super IO configuration Provide NCT6106D super IO configuration settings WatchDog count mode Second WatchDog count mode Selection Configuration options Second Minute...

Страница 96: ...uration Serial Port Enabled Enable or Disable serial Port COM Configuration options Disabled Enabled Change Settings Auto Select an optimal settings for super IO device Configuration options as below...

Страница 97: ...hange the speed mode for serial port BaudRate Configuration options Low Speed High Speed 4 6 2 Serial Port 2 Configuration Serial Port Enabled Enable or Disable serial Port COM Configuration options D...

Страница 98: ...eed Mode Low Speed Change the speed mode for serial port BaudRate Configuration options Low Speed High Speed 4 6 3 Digital I O Configuration Digital I O Pin1 Input Configure Digital I O Pin Configurat...

Страница 99: ...s Input Output High Output Low Digital I O Pin5 Output Low Configure Digital I O Pin Configuration options Input Output High Output Low Digital I O Pin6 Output Low Configure Digital I O Pin Configurat...

Страница 100: ...100 BIOS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 19 4 7 1 Smart FAN Smart FAN Function Enabled...

Страница 101: ...ion SYS Smart Fan Mode Manual Mode SYS Smart FAN Mode selection Configuration options Manual Mode Thermal Cruise Mode SMART FAN IV Mode CPU Smart Fan Mode Manual Mode CPU Smart FAN Mode selection Conf...

Страница 102: ...IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 21 4 8 Preheat Function Configuration Preheat Function Disabled Check CPU and system temperature If either is lower than specific temperature then do prehea...

Страница 103: ...w and functions Appendix IND100077 227 BQ370 MH3 BIOS Step 22 BQ370 MH3 BIOS 4 9 S5 RTC wake settings Wake system from S5 Disabled Enabled or Disabled system wake on alarm event Configuration options...

Страница 104: ...w and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 23 4 10 Serial Port Console Redirection Console Redirection Disabled Enabled or Disabled Console Redirection Configuration options...

Страница 105: ...105 BIOS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS Step 24 BQ370 MH3 BIOS 4 11 Intel TXT information Display Intel TXT information...

Страница 106: ...USB devices available only for EFI application Configuration options Enabled Disabled Auto XHCI Hand off Enabled This is a workaround for OSes without XHCI hand off support This XHCI ownership change...

Страница 107: ...ions UEFI and Legacy Legacy Only UEFI Only Network UEFI Control the execution of UEFI and Legacy PXE OpROM Configuration options Do not launch UEFI Legacy Storage UEFI Control the execution of UEFI an...

Страница 108: ...108 BIOS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 27 4 14 NVMe Configuration Display NVMe controller or Drive information...

Страница 109: ...view and functions Appendix IND100077 227 BQ370 MH3 BIOS Step 28 BQ370 MH3 BIOS 4 15 Network Stack Configuration Network Stack Disabled Enabled or disabled UEFI Network Stack Configuration options Dis...

Страница 110: ...110 BIOS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 29 5 Chipset...

Страница 111: ...ctions Appendix IND100077 227 BQ370 MH3 BIOS Step 30 BQ370 MH3 BIOS 5 1 System Agent SA Configuration VT d Enabled VT d capability Configuration options Disabled Enabled 5 1 1 Memory configuration Dis...

Страница 112: ...view and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 31 Max TOLUD Dynamic Maximum value of TOLUD Configuration options As above picture 5 1 2 Graphic Configuration Graphic configura...

Страница 113: ...s Auto Keep IGFX enabled based on the setup options Configuration options Auto Disabled Enabled PSMI Support Disabled Enable or disable PSMI Configuration options Disabled Enabled DVMT Pre Allocated 3...

Страница 114: ...Enable Root Port Auto Enable or Disable the Root Port Configuration options Disabled Enabled Auto Max Link Speed Auto Configure PEG 0 1 0 Max Speed Configuration options Auto Gen1 Gen2 Gen3 Detect No...

Страница 115: ...Lan1 Controller Configuration options Disabled Enabled Lan2 Controller Enabled Enable or Disable onboard Lan2 Configuration options Disabled Enabled Lan2 PXE DpROM Disabled Enable or Disable boot opt...

Страница 116: ...ed Enabled Lan4 PXE DpROM Disabled Enable or Disable boot option for Lan4 Controller Configuration options Disabled Enabled Pcie P11 SSC Auto Pcie P11 SCC percentage Auto Keep HW default no BIOS overr...

Страница 117: ...2_1 PCI Express Root Port 3 Enabled Control the PCI Express Root Port Configuration options Disabled Enabled ASPM 3 Disabled Set the ASPM level Force L0s Force all links to L0s State Auto BIOS auto co...

Страница 118: ...Root Port 4 Enabled Control the PCI Express Root Port Configuration options Disabled Enabled ASPM 4 Disabled Set the ASPM level Force L0s Force all links to L0s State Auto BIOS auto configure Disable...

Страница 119: ...ess Root Port 5 Enabled Control the PCI Express Root Port Configuration options Disabled Enabled ASPM 5 Disabled Set the ASPM level Force L0s Force all links to L0s State Auto BIOS auto configure Disa...

Страница 120: ...t Port 13 Enabled Control the PCI Express Root Port Configuration options Disabled Enabled ASPM 13 Disabled Set the ASPM level Force L0s Force all links to L0s State Auto BIOS auto configure Disabled...

Страница 121: ...ss Root Port 21 Enabled Control the PCI Express Root Port Configuration options Disabled Enabled ASPM 21 Disabled Set the ASPM level Force L0s Force all links to L0s State Auto BIOS auto configure Dis...

Страница 122: ...mines how SATA controller operate Configuration options AHCI Intel RST Premium with Intel Optane System Acceleration Port 0 Enabled Enable or Disable SATA Port Configuration options Disabled Enabled P...

Страница 123: ...70 MH3 BIOS Step 42 BQ370 MH3 BIOS 5 2 3 USB configuration XHCI Compliance Mode Disabled Options to enable Compliance Mode Configuration options Disabled Enabled USB Power Selection 5V_Dual Select 5V_...

Страница 124: ...S Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 43 5 2 4 HD Audio Configuration HD audio Enabled Control Detection of the HD Audio device Configuration options Disabled E...

Страница 125: ...OS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS Step 44 BQ370 MH3 BIOS 5 2 5 Serial IO Configuration I2C0 Enabled Enables Disables Serial IO Controller Configuration options Disabled E...

Страница 126: ...126 BIOS Overview and functions Appendix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 45 6 Security Administrator Password Set setup Administrator Password User Password Set User Password...

Страница 127: ...e or Disable system secure boot Configuration options Disabled Enabled Secure Boot mode Custom Secure boot mode option Configuration options Standard Custom Restore Factory keys Force system to user m...

Страница 128: ...dix IND100077 227 BQ370 MH3 BIOS BQ370 MH3 BIOS 47 6 1 1 Key management This sheet describe keys installation and status for secure boot We suggest user do not change these default setting if you are...

Страница 129: ...indefinite waiting Bootup NumLock State On Select the keyboard NumLock state Configuration options On Off Quick Boot Disable Enable or disable Quick Boot option Configuration options Disabled Enabled...

Страница 130: ...49 8 Save Exit Save changes and Exit Exit system setup after saving the changes Discard changes and Exit Exit system setup without saving the changes Save changes and Reset Reset the system after savi...

Страница 131: ...Volume1 b Select RAID Level Available options depend on how many drives are connected 2 drives 1 RAID0 Stripe a Increased Read and Write performance b No redundancy c Not recommended for critical sys...

Страница 132: ...boot to enter RAID BIOS menu Intel RST Option ROM After you have entered RAID BIOS the steps to create RAID volume are the same as for step 3 in procedure for UEFI above Available RAID levels RAID 0 S...

Страница 133: ...ddition to PCIe graphics card To enable onboard display outputs when PCIe graphics is present 1 Press Del key during boot to enter BIOS menu 2 From first BIOS menu navigate to Chipset System Agent SA...

Страница 134: ...dog Timer I has four registers in Logic Device 8 When CR30h bit0 1 Watchdog Timer circuit is activated then CRF5 F6 and F7h are meaningful Watchdog Timer reset source selection is located at Logic Dev...

Страница 135: ...chdog timer directly b To stop the watchdog timer please set the timer counter register to 00h first then clear watch dog status register 13 UART RS485 auto flow control and data transit For rev B NCT...

Страница 136: ...ntrol Via RTS signal controlled by user application Note Configuration performed in computer BIOS Note Configuration performed in computer BIOS 9 pin USB3 0 3 1 3 2 TYPE A 1 2 3 4 9 8 7 6 5 PIN 01 VCC...

Страница 137: ...side connector pinout will have lanes 0 3 reversed in order i e lane 3 will be on pin 1 n and 3 p while lane 0 will be on pin 10 n and 12 p 9 pin Amplified Mono Stereo Audio Out DSUB Female 5 4 3 2 1...

Страница 138: ...TX to RX Note The jumper for force of transmitter Forced TX y is open by factory default For some custom models this jumper is preset to closed active in that case unit has to be opened and jumper se...

Страница 139: ...Please note At least 30GB of free disk space is needed on the unit in order to create the 16GB USB Memory Stick It can take up to 1 hour to create the USB Memory Stick DOC207939 1 Revision 03 Hattelan...

Страница 140: ...mpletely wiped of all data The USB stick chosen will have all its data deleted 4 The program will run for a couple of minutes the speed of the creator depends on the speed of the operating system and...

Страница 141: ...ot support Legacy BIOS only UEFI is supported 1 3 2 How to use Boot into your USB stick by pressing F7 key during start up of your Hatteland Technology Panel Computer Some of our computer models uses...

Страница 142: ...ll be wiped and all data on the drive will be lost After pressing yes the program will do everything needed for the recovery automatically When finished you are asked to restart or shut down your comp...

Страница 143: ...ed 2 If your Windows RE status is Disabled or did not boot into Windows Recovery Environment during boot test do the following steps a Open Command Line window with administrator rights b Run the foll...

Страница 144: ...fault condition ordinary persons should not be exposed to parts comprising energy sources capable of causing injury Instructed person Instructed person is a term applied to persons who have been instr...

Страница 145: ...Battery Obligated to use battery specified for the product Altitude Products are designed for a max operating altitude of 2000m Installation Description Mounting brackets Only bracket defined specifi...

Страница 146: ...146 IND100078 87 IEC62368 policy Appendix Chassis Thermal Heat note Active HTC03 HT20370 HT20470 units might feel hot to the touch externally this is normal and expected...

Страница 147: ...This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against...

Страница 148: ...Of Goods Information Make sure you surround the product with the following material whenever possible Use the original packaging from manufacturer firm foam material bubble wrap lots of PadPack paper...

Страница 149: ...ION For any claims the following documentation is required and must forwarded to the company or their agent invoice way bill and or bill of landing and or statement of arrival inspection document besi...

Страница 150: ...ths Note This is a general listing for a varity of OS s Hatteland Technology can factory install depending on unit Please check specification for your unit to verify type of OS installed in order to r...

Страница 151: ...151 Appendix IND100077 24 User Notes...

Страница 152: ...1 Revised after internal reviews 01 ALL SE 13 Apr 2021 Release for internet 02 CH HS SE 17 Aug 2021 18 Aug 2021 Added Module Matrix overview page 37 38 Added note for chassis heat page 137 03 VM GM SE...

Страница 153: ...153 Revision History IND100077 249...

Страница 154: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...

Отзывы: