VENTILATION/AIR SUPPLY
Around 95 m³ of moist air is vented out of the drying cabinet every hour when it is
running. You should therefore ensure that the room is well ventilated to replace the
damp air that is extracted.
CONNECTING TO VENTILATION
The drying cabinet should be connected to a ventilation system that meets the
relevant standards.
The drying cabinet can be connected to an extraction system in two ways, either
by using a draught break, or by connecting directly to a mechanical extractor
duct.
If the drying cabinet is connected to an existing ventilation system a draught break
must always be used, to prevent interference with the general
ventilation in the premises.
Direct connection should only be used when a dedicated extractor duct is
provided for the drying cabinet, with a capacity of 95 m³ per hour.
The drying cabinet has been tested and set up at the factory for connection with
a draught break.
Exhaust vent on the cabinet
Fit the supplied collar (1) into the hole in the top of the cabinet. Turn it
clockwise so that the tabs engage with the cut-outs in the top of the cabinet.
1
Locking tab on collar
Slot in top of cabinet for
fastening hook