background image

Product

Part number

Description

CMi2130 

(gen.3)

1050124

Integrated MCM for Itron CF 51/55/

ECHO II, Gateway for Mobile Network 

(0T/0)

CMi2130 

(gen.3)

1100244

Integrated MCM for Itron CF 51/55/

ECHO II, Gateway for Mobile Network 

(8T/128 meters)

CMip2130 1050018

Power supply 230 VAC

contAct InforMAtIon

elvaco AB technical support:

Phone: +46 300 434300 

E-mail: support @elvaco.com 

Online: www.elvaco.com

technIcAl sPecIfIcAtIons

Mechanics

Protection class

IP54

Mounting

In Itron CF 51/55/ECHO II meter

SIM card

Slide, standard size

Electrical connections

Supply voltage

Supplied from Itron meter

Connection M-Bus*

Push-pull connector, cable area 0.2-0.75 

mm²

Electrical characteristics

Nominal voltage

100-240 VAC (+/- 10%)

Frequency

50/60 Hz

Power consumption (max) <6 W

Power consumption (nom) <1 W
Installation category

CAT 2

User interface

Green LED

Power

Red LED

Error

Yellow LED

GSM status

Blue LED

USB active

Push button

Factory reset

Configuration

SMS, HTTP, GSM CSD, Telnet

Integrated M-Bus Master*

M-Bus baud rate

2400 and 9600 bit/s

Nominal voltage

28 VDC

Maximum unit loads

8T/12 mA (in addition to the meter in 

which the MCM is mounted)

Maximum cable length

1000 m (100 nF/km, maximum 90 

Ω

)

Approvals

EMC

EN 61000-6-2, EN 61000-6-3, EN 301 498-

1, EN 310 489-7

Safety

EN 61010-1, CAT 2

orderIng InforMAtIon

sAfety

The warranty does not cover damage to the product caused 

by usage in any other way than described in this manual. 

Elvaco AB can not be liable for personal injury or property 

damage caused by usage in any other way than described in 

this manual.

status report indicates missing APn

 

This may be due to the fact that the auto APN detection is 

missing information about your network provider. The APN can 

be set manually. See the CMi2130 Operations guide for more 

information.

e-mail settings have been configured but no e-mails are received

 

This may be due to one of the following reasons:

• 

No/no valid recipients have been set. Set recipients by 

using the command 

qset email [recipient]

.

• 

The wrong SMTP server is set. Check current SMTP 

server by using the command 

status

. If no SMTP server 

has been set, use the command 

qset

 

email [recipient] 

[server] 

to set it manually.

• 

The report is not correctly activated. Use the command 

sch

 to schedule e-mail Push Reports (see table).

• 

There is not enough credit on the SIM card.

*Only applicable to the CMi2130 equipped with M-Bus Master

Отзывы: