background image

© 2020, Elvaco AB. All rights reserved. The documentation and product are provided on an “as is” basis only and may contain deficiencies or in-
adequacies. Elvaco AB takes no responsibility for damages, liabilities or other losses by using this product. No part of the contents of this manual 
may be transmitted or reproduced in any form by any means without the written permission of Elvaco AB. Printed in Sweden.

 

CMeX10S-13S Quick manual A4 English

Document id: 1090031

Version:  5.0  

M-Bus

M-Bus standard

EN 13757

M-Bus baud rate

300, 2400 Bit/s

Maximum connected M-Bus 
unit loads 
(1T=1,5mA)

CMeX10S: 32T (48mA) 
CMeX11S: 64T (96mA) 
CMeX12S: 128T (192mA) 
CMeX13S: 256T (384mA) 

Maximum cable length

5000 m

Maximum load capacitance

1.5 uF

Nominal voltage

42 VDC

IR interface

Yes

Pass through

Yes. Maximum of 4 CMeX Series products side 
by side

Compatibility

All M-Bus meters, all ABB meters with IR 
interface, CMeX Series products

Approvals

EMC

EN 61000-6-2, EN 61000-6-3, FCC 47 CFR

Safety

EN 62368-1 2018, UL 62368-1:2014 Ed.2],  
CSA C22.2#62368-1:2014 Ed.2]

CONTACT 

Technical support

Phone: +46 300 434300 
E-mail: support @elvaco.com 
Online: www.elvaco.com

TECHNICAL SPECIFICATIONS

LED INDICATIONS

Green PWR LED 

PWR LED indicates mains supply.

Mode

Description

Visual

Permanently on

Mains power connected

Permanently off

No mains power 
connected

Red ERR LED 

ERR LED indicates M-Bus 2-wire bus status.

Mode

Description

Visual

Permanently on

Short circuit of the M-Bus 
2-wire bus

Permanently off

Normal mode, idle

Short flash every 
second

No M-Bus unit loads 
connected

Flashing for 1 
second

M-Bus unit load collision

Yellow RX LED 

RX LED indicates communication from M-Bus unit loads to DTE.

Mode

Description

Visual

On/Flashing

M-Bus unit load is 
transmitting data

Off

M-Bus unit load is not 
transmitting data

Yellow TX LED 

TX LED indicates communication from DTE to M-Bus unit loads.

Mode

Description

Visual

On/Flashing

DTE is transmitting data

Off

DTE is not transmitting 
data

SAFETY

The warranty does not cover damage to the product caused by usage in 
any other way than described in this manual. Elvaco AB can not be liable 
for personal injury or property damage caused by usage in any other way 
than described in this manual.

Mechanics

Protection class

IP20

Dimensions

90x65x108 mm

Weight

220 g

Connection M-Bus

Pin terminal solid wire 0.6-0.8 Ø mm and screw 
terminal cable 0.25-2.5 mm², 0.5 Nm tightening 
torque

Mounting

DIN mounted

Power supply

Screw terminal cable 0.75-2.5 mm², 0.5 Nm 
tightening torque

Electrical

Nominal voltage

100-240 VAC

Voltage range

-10 % to +10 % of nominal voltage

Frequency

50/60 Hz

Power consumption (max)

25 W

Power consumption (nom)

0.07 W x M-Bus unit loads + 1.5 W

Overvoltage category

CAT 2

Environmental

Operating temperature range

-30 °C to +55 °C

Storage temperature range

-40 °C to +85 °C

Pollution

Degree 2

Operating altitude

0-2000 m