![ELTEX IONSTAR RX3 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/eltex/ionstar-rx3/ionstar-rx3_operating-instructions-manual_2397290012.webp)
12
BA-en-2058-1808_IONSTAR RX3
Locating the discharging bar
The best possible discharging results are achieved if the bar is located in
areas with minimum web capacities. In practical terms this means placing
the bar with maximum distances from the machine environment, i.e. no
discharging against the idler roller.
A rough guideline:
No objects of conductive grounded material must be mounted within a
minimum distance of 260 mm from the tip array (Fig. 4). A cylindrical
space with the radius R of the bar distance to the web ought to be kept
free of any conductive material (Fig. 4).
Distance frontal: min. 60mm!
Fig. 4:
Zone free of con-
ductive grounded
material around
the discharging
bar
Z-
10
99
88d
_4