Eltek Smartpack2 Скачать руководство пользователя страница 5

1 Introduction 

User's Guide

 

Smartpack2 Master Controller

  

 

  

350020.013, Issue 2.0, 2014 Jan

 

5

 

1. Introduction 

The  advanced 

Smartpack2 Master

  controllers  are  developed  for  Eltek’s 

Flatpack2

  DC 

power systems that implement the 

Smartpack2

-based distributed control system. 

About this Guide 

This  booklet  provides  users  of 

Smartpack2

-based  DC  power  systems  with  the  required 

information  for  operating  the  system  using  the 

Smartpack2 Master

’s  front  panel.  The 

booklet  also  describes  the 

Smartpack2 Master

  controller’s  building  blocks,  external 

connections and technical specifications. 

Read also the 

generic and site specific documentation

 for your DC

 

power system. 

For  detailed  functionality  description,  browse  and  search  through  the 

Functionality 

Description 

topic in 

PowerSuite Online Help

 or 

CWUI Online Help

. Notice that you must 

log in to access Online Help

 (contact your Eltek representative) 

System Diagram 

— 

Flatpack2

 Power System w/SP2 

The generic 

Smartpack2

 (SP2) distributed control system — used in 

Flatpack2

 PS systems 

— monitors and controls the whole system, and consists of the 

Smartpack2

 

Master

 (SP2M) 

controller, the 

Smartpack2

 

Basic

 (SP2B) controller and the 

I/O Monitor2

 CAN node. 

The 

Smartpack2

 

Master

 serves as the local user interface between you and the system. The 

system may also be configured via the Controller’s Web-based User Interface (CWUI) on 
a  standard  web  browser,  and  via  the 

PowerSuite

  PC  application.  The 

Smartpack2

 

Basic

 

monitors and controls the power system’s internal wiring and supplies the CAN bus with 
power. The 

I/O Monitor2

 CAN node implements input and output signals. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Figure 1   Typical Flatpack2 DC power system for telecom and industrial equipment, fed from external AC mains or 

DC supply. It consists of rectifiers in power shelves, master and basic controllers, DC distribution, etc. 

 

 

Battery string #1 

AC mains 
supply 
selector 

Temp. 

Sensors 

LVLD 

LVBD 

Fuse Alarm 

AC Fuses, external 

(230VAC or 400VAC 

or 85-300VDC) 

Battery 

Fuses 

Load Fuses 
& MCBs 

Flatpack2 HE 
rectifiers 

CAN Bus 

DC 

Distribution 

DC Output 

(24V, 48V 

 or 60V) 

Flatpack2 

System

 

Ethernet 

cable 

Internet 

Telecom and 

Industrial  

equipment 

Smartpack2 
Master Controller 

Smartpack2 
Basic Controller 

Alarm Outputs NC-C-NO 

Config. Inputs 

CWUI 

(C

ontroller’s web-

based user interface) 

I/O Monitor2 
CAN node 

AC Input 

(Single- or 3-phase 

or DC Input) 

OR 

Содержание Smartpack2

Страница 1: ...350020 013 Monitoring and Control Units Powerpack Flatpack2 Minipack DC Power Supply Systems User s Guide Smartpack2 Master Controller...

Страница 2: ...regular basis Indoor installations in dusty or humid areas require appropriate air filtering of the room or filtering of the air entering the DC power system Follow the instructions given in Generic...

Страница 3: ...Introduction User s Guide Smartpack2 Master Controller 350020 013 Issue 2 0 2014 Jan 3 Part number for Smartpack2 Master Controller 242100 500 350020 013 Issue 2 0 2014 Jan Published 2014 03 06 mafen...

Страница 4: ...ware Upgrade Controller 13 Firmware Upgrade from the SD Card 13 Firmware Upgrade from a Computer 14 Overview LAN Devices and Firmware Files PC S19 Format 14 3 About Power System Configuration 15 Logic...

Страница 5: ...m and consists of the Smartpack2 Master SP2M controller the Smartpack2 Basic SP2B controller and the I O Monitor2 CAN node The Smartpack2 Master serves as the local user interface between you and the...

Страница 6: ...are implemented in the Smartpack2 Master controller as mentioned below Graphical TFT high contrast high resolution color display for easy navigation LEDs for local visual alarming Major Minor Power O...

Страница 7: ...the handle s knob slightly outwards use your fingers or a pen and 2 then slide the handle to the left the controller s right side opens 3 To close it slide the handle to the right the controller s ri...

Страница 8: ...ends and plug it in one of the CAN ports on the last connected CAN node CAN Bus Cabling In addition to the two dedicated wires for communication the CAN bus multi wire cable must integrate wires for t...

Страница 9: ...ugh the graphical menu structure via the following 6 front keys Press on the key to change from Status Mode to Menu Mode and to select options enter values Press the key to navigate to previous level...

Страница 10: ...imated icons keys to press alarms system time etc Multi Info field Display area M Status Battery Bank Displayed in or in Ah Display area B Menu Mode Main Menu Options Level 1 Menu Icons Menu Names Men...

Страница 11: ...Using the ENU program 1 Select the controller 2 Click in the Configuration button 3 Change from default 192 168 10 20 0 0 0 0 to e g IP address 169 254 52 133 255 255 0 0 Ping 169 254 52 133 first to...

Страница 12: ...er Controller 12 User s Guide Smartpack2 Master Controller 350020 013 Issue 2 0 2014 Jan o o Technical Specifications o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o...

Страница 13: ...grade and configuration files stored in the SC card must have specific file names Open the controller using your fingers or a pen see steps 1 2 above or chapter Opening and Closing Smartpack2 Master C...

Страница 14: ...rogram ENU will transfer the specific firmware file s19 format from a LAN connected computer to the device or hardware platform LAN Device File Name examples File Type Smartpack S Smartpack S_ part _...

Страница 15: ...user interface built in the controllers The PowerSuite program A PC application run on computers using MS Windows operating systems Logical Groups or Menu Options All the mentioned functions characte...

Страница 16: ...llowed at this level using a Pin Code NOTICE The default Service Access Level password or Pin Code is 0003 which may be changed for security reasons The parameters are organized in system oriented gro...

Страница 17: ...commands such as resetting manual alarms deleting the event log starting battery tests etc Issuing commands is allowed at this level using a Pin Code NOTICE The default Service Access Level password...

Страница 18: ...rtpack2 Master Controller s submenu Logs Report Active Alarms Description Value Limit Alarm Group Output Note BatteryTemp 1 1 42 30 SymmVolt 1 1 12 91 1 50 Alarm Group 15 RectifierError 1 1 Minor Alar...

Страница 19: ...Inventory Report The Inventory Report presents information that describes the power system the site s name serial number installation and service dates software name etc Example of Inventory Report ta...

Страница 20: ...the Service Access Level NOTICE Using the CWUI Controller Web based User Interface or PowerSuite you can also up download to other storage media e g computer hard discs The Up and Download options ar...

Страница 21: ...storing the files on the SD card you must rename them so that they conform to the specific file names described below For example if you receive the file SmartPack2_Basic_405007 009_V1 1 mhx to upgrad...

Страница 22: ...ontrol units if several units of the same type are connected to the CAN bus the Smartpack S controller will request you to specify the CAN bus ID number of the unit to upgrade FTP Client The files sto...

Страница 23: ...nhibiting or similar The generated alarm activates a preprogrammed group of relay outputs an alarm output group AOG The alarm monitors most commonly used configuration parameters are Refer to the Alar...

Страница 24: ...ctions events are usually defined from factory Logical alarm monitors only compare the measured input signal with a logical state normally open or closed The user can define the alarm group that the m...

Страница 25: ...rs LVD monitor the battery voltage and controls the LVD contactors Analogue and numerical alarm monitors compare the measured input with one to four user defined values or limits two above normal valu...

Страница 26: ...tivate Parameters for Numerical Alarm Monitors N1 Example to monitor numeric values such as the number of rectifiers errors etc Description Value Unit Label Note Monitor Enable Disable Enable Activate...

Страница 27: ...e options b MajorHigh AlarmLevel 280 Volt AC Major High upper limit MajorHigh AlarmGroup Mains Alarm Selects the alarm group to activate MinorHigh AlarmLevel 260 Volt AC Minor High upper limit MinorHi...

Страница 28: ...OT reconnect the LVD contactor until Mains is ON again d Temperature Dependent Used with LVD contactors that disconnect the battery bank LVBD Check this option if you want that the LVD alarm monitor w...

Страница 29: ...ng contactors Usually the first seven alarm output groups have alarm relay outputs already assigned to them from factory Factory Default Settings Typically alarm output groups 8 through 18 are listed...

Страница 30: ...w Battery Alarm AOG 7 Rectifier Alarm AOG 8 Gen Set AOG 9 Alarm Group 9 10 Alarm Group 10 17 Alarm Group 17 18 OutpBlocked AOG 19 LVBD AOG 20 LVLD AOG 1 In the example above Alarm relay output 1 is us...

Страница 31: ...ent for a certain period of time entered in the Output Test Timeout sec in PowerSuite Issuing commands is allowed using a Pin Code NOTICE The default Service Access Level password or Pin Code is 0003...

Страница 32: ......

Отзывы: