background image

2

agent or similarly qualified persons in order to avoid a hazard.

• Do not obstruct the fan or exhaust grille to ensure optimum air passage.

• Ensure adequate air return into the room in compliance with existing regulations in 

order to ensure proper device operation.

• If the environment in which the product is installed also houses a fuel-operating device 

(water heater, methane stove etc., that is not a “sealed chamber” type), it is essential 

to ensure adequate air intake, to ensure good combustion and proper equipment 

operation.

• Install the product so that the impeller is not accessible from the air outlet side as 

verified by contact with the Test Finger (test probe “B” of the norm EN61032) in 

compliance with the current safety regulations.

• Ceiling installation 

  In order to guarantee the IPX4 degree of protection against moisture in case of ceiling 

installation, use the appropriate ceiling mount kit, which is included in the box. Use 

only the rear entry hole for supply cables. If there is a possibility of condensation 

along the air discharge duct, provide a drainage system to prevent condensation from 

discharging into the environment through the fan. 

 

Attention: 

do not mount the product on the ceiling without this kit.

• Window installation 

  In case of window installation it is  necessary to use the appropriate window kit, which 

is not included. 

 

Attention:

 do not mount the product on the window without this kit.

Model

Airflow

Static pressure

Pa max

Power

W max

Sound pressure

dB(A) @3m

m

3

/h 

l/s

MORI dMEV  II T

83/47/29/21 23,1/13/8/6

27

2,5

26/23/13/11

MORI dMEV  II HT 83/47/29/21 23,1/13/8/6

27

2,5

26/23/13/11

INTRODUCTION

MORI dMEV (fig. 1) is a decentralised mechanical ventilation unit designed to ensure air 

extraction in small/medium-sized rooms such as bathrooms, toilets and kitchens.  

Suitable for air discharge directly to the outside or in the presence of short ducted system. 

Wall, ceiling or window installation (fig. 2).

TECHNICAL SPECIFICATIONS

• Material: high quality, impact and UV-resistant ABS colour RAL 9010.

• Design front cover removable for cleaning without the use of tools.

• Rear reinforcement ring to prevent spigot deformation during installation.

• High efficiency aerodynamic fan with “winglet” blades to optimise quietness and 

efficiency.

• Single phase EC Brushless motor with integral thermal protection.

• Motor mounted on high quality ball bearings.

• The fan is double insulated: no earth connection is required.

• Trickle speed selectable during installation. 

• Option to boost from trickle (or from off) through LS connection or pull cord.

• Installation type selection available (through wall or ducted).

• Timer and Integral Humidistat versions available.

• IPX4 degree of protection.

•Power supply 220V to 240V~ 50Hz.

Содержание MORI dMEV II HT

Страница 1: ...ch as alcohol insecticides gasoline etc If any abnormalities in operation are detected disconnect the device from the mains supply and contact a qualified technician immediately Use original spare par...

Страница 2: ...dow installation it is necessary to use the appropriate window kit which is not included Attention do not mount the product on the window without this kit Model Airflow Static pressure Pa max Power W...

Страница 3: ...ia a dedicated trimmer g 17B The fan works at the selected trickle speed or off and can be boosted using the integrated pull cord switch or light switch Once the boost switch is turned off the fan wil...

Страница 4: ...4 35 EU Low Voltage Directive LVD 2014 30 EU Electromagnetic Compatibility EMC in conformity with the following standards Electrical Safety EN60335 1 2012 A11 A13 EN 60335 2 80 2003 A1 A2 Electromagne...

Страница 5: ...5 MORI dMEV II 99 mm 7 8 4 6 5 6 MOUNTING AND ELECTRICAL WIRING 3...

Страница 6: ...6 4 x 5 mm 9A 10A 11A 12A SURFACE CABLE H03VV F H05VV F 10mm 2 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT d 13A d...

Страница 7: ...0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT 14 15 The ceiling mounting gasket should be sandwiched between the fan and the ceiling ensuring that it is flat against the ceiling Included in...

Страница 8: ...MORI dMEV II T MORI dMEV II HT 16E JUMPER INSTALLATION AIRFLOW 1 2 3 through wall OFF through wall 6L s through wall 8L s through wall 13L s in room OFF in room 6L s in room 8L s in room 13L s 18 MORI...

Страница 9: ...9 21 CLICK 19 20 22 23 ON OFF...

Страница 10: ...out as and when required but please note intervals between cleaning should not exceed 6 months The installer should explain this cleaning regime to the homeowner occupier and ask the homeowner occupi...

Страница 11: ...cling treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment Improp...

Страница 12: ...anual control no DCV Local demand control o1 Maximum internal leakage rate N A N A o2 Maximum external leakage rate N A N A p1 Internal mixing rate N A N A p2 External mixing rate N A N A q Visual fil...

Страница 13: ...13 NOTES...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...Elta Fans Limited Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom T 44 0 1384 275800 F 44 0 1384 275810 E bs eltafans co uk 001435 05 0518...

Отзывы: