background image

12

a) Mark

-

ELTA FANS

ELTA FANS

b)  Model

-

MORI dMEV II T

MORI dMEV II HT

c) SEC class 

-

E

C

c1) SEC warm climates 

kWh/m2.a

-5,4

-11,3

c2) SEC average climates

kWh/m2.a

-13

-25,7

c3) SEC cold climates

kWh/m2.a

-26,4

-50,7

Energy label

-

No

No

d)  Unit typology

-

Residential - unidirectional

Residential - unidirectional

e)  Type of drive

-

multi speed drive

multi speed drive

f)  Type of Heat Recovery System

-

absent

absent

g)  Thermal efficiency of heat recovery

%

N/A

N/A

h)  Maximum flow rate

m3/h

83

83

i)  Electric power input at maximum flow rate

W

2,6

2,6

j)  Sound power level (L

WA

)

dBA

44

44

k)  Reference flow rate

m3/h

61

61

l)  Reference pressure difference

Pa

10

10

m)  Specific Power Input (SPI)

W/m3/h

0,028

0,028

n1) Control factor

-

1

0,65

n2) Control typology

-

Manual control (no DCV)

Local demand control

o1) Maximum internal leakage rate

%

N/A

N/A

o2) Maximum external leakage rate

%

N/A

N/A

p1) Internal mixing rate

%

N/A

N/A

p2) External mixing rate

%

N/A

N/A

q)  Visual filter warning

-

N/A

N/A

r)  Instructions to install regulated grilles

-

check the instruction booklet check the instruction booklet

s)  Internet address for preassembly/disassembly instructions

-

www.eltafans.com

www.eltafans.com

t)  Airflow sensitivity to pressure variations

%

N/A

N/A

u)  Indoor/outdoor air tightness

m3/h

52

52

v1) AEC - Annual electricity consumption - warm climates

kWh

0,4

0,2

v2) AEC - Annual electricity consumption - average climates

kWh

0,4

0,2

v3) AEC - Annual electricity consumption - cold climates

kWh

0,4

0,2

w1) AHS - Annual heating saved - warm climates

kWh

6,3

11,9

w2) AHS - Annual heating saved - average climates

kWh

14

26,2

w3) AHS - Annual heating saved - cold climates

kWh

27,3

51,3

ErP Directive - Regulations 1253/2014 1254/2014

Содержание MORI dMEV II HT

Страница 1: ...ch as alcohol insecticides gasoline etc If any abnormalities in operation are detected disconnect the device from the mains supply and contact a qualified technician immediately Use original spare par...

Страница 2: ...dow installation it is necessary to use the appropriate window kit which is not included Attention do not mount the product on the window without this kit Model Airflow Static pressure Pa max Power W...

Страница 3: ...ia a dedicated trimmer g 17B The fan works at the selected trickle speed or off and can be boosted using the integrated pull cord switch or light switch Once the boost switch is turned off the fan wil...

Страница 4: ...4 35 EU Low Voltage Directive LVD 2014 30 EU Electromagnetic Compatibility EMC in conformity with the following standards Electrical Safety EN60335 1 2012 A11 A13 EN 60335 2 80 2003 A1 A2 Electromagne...

Страница 5: ...5 MORI dMEV II 99 mm 7 8 4 6 5 6 MOUNTING AND ELECTRICAL WIRING 3...

Страница 6: ...6 4 x 5 mm 9A 10A 11A 12A SURFACE CABLE H03VV F H05VV F 10mm 2 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT d 13A d...

Страница 7: ...0 5 1 5 mm2 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 BASE STD T HT 14 15 The ceiling mounting gasket should be sandwiched between the fan and the ceiling ensuring that it is flat against the ceiling Included in...

Страница 8: ...MORI dMEV II T MORI dMEV II HT 16E JUMPER INSTALLATION AIRFLOW 1 2 3 through wall OFF through wall 6L s through wall 8L s through wall 13L s in room OFF in room 6L s in room 8L s in room 13L s 18 MORI...

Страница 9: ...9 21 CLICK 19 20 22 23 ON OFF...

Страница 10: ...out as and when required but please note intervals between cleaning should not exceed 6 months The installer should explain this cleaning regime to the homeowner occupier and ask the homeowner occupi...

Страница 11: ...cling treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment Improp...

Страница 12: ...anual control no DCV Local demand control o1 Maximum internal leakage rate N A N A o2 Maximum external leakage rate N A N A p1 Internal mixing rate N A N A p2 External mixing rate N A N A q Visual fil...

Страница 13: ...13 NOTES...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...Elta Fans Limited Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom T 44 0 1384 275800 F 44 0 1384 275810 E bs eltafans co uk 001435 05 0518...

Отзывы: