6 Project planning information
6 .1 Flame control
The flame is monitored by a combined ignition/ionization
electrode as standard.
Flame control with UV sensor is only necessary if furnace
temperatures of 1050°C for direct heating or 950°C for indirect
heating are exceeded. Furthermore, we recommend using
bend-resistant Kanthal electrodes for ignition (standard with
ECOMAX..C) in this case.
We recommend the UV sensor UVS 10D1 with integral purging
air connection (Order No. 84315202) for burner length 545.
For burner lengths greater than 545 mm and for burner size
Ecomax 0, the UV sensor UVS 10L1 (Order No. 84315203) with
lens is required. For attaching the UVS 10, an adapter set Eco-
UVS 10 /E (Order No. 22800079) is available.
ECOMAX
®
burner with ionization control
ECOMAX
®
burner with UV control