ECOMAX · Edition 02.11
37
7 Technical data
Heating: direct with eductor or indirect in radiant tube.
Control type: On/Off.
Control range: approx. 1:3.
Flame velocity: approx. 120 to 150 m/s.
Flame control: direct ionization control (UV control as an
option).
Ignition: direct, electrical.
Recuperator:
ECOMAX..C:
ceramic (SiSiC), max. application temperature 1300°C,
ECOMAX..M:
cast steel, max. application temperature 1150°C,
ECOMAX..FTR:
metallic, max. application temperature 950°C.
Burner
Output [kW]
Flame length [mm]*
ECOMAX 0
25
250
ECOMAX 1
36
350
ECOMAX 2
60
450
ECOMAX 3
100
600
ECOMAX 4
180
800
ECOMAX 5
250
800
ECOMAX 6
500
800
* Visible range for natural gas operation in the open air,
max. connection rating and air index 1.15.
7 .1 Efficiency
Heating: direct.
Flue gas extraction: 100%.
Lambda: 1.1.
Duty cycle: 80%.
Diagrams for efficiency, flue gas temperature and air preheat-
ing – see page 38 (ECOMAX..C), page 39 (ECOMAX..M),
page 40 (ECOMAX..FTR).