background image

  Edition 02.10

© 2008 – 2010 Elster GmbH

 www.docuthek.com

GB NL SK

D

Please read and keep in a safe place

 Please read through these instructions 

carefully before installing or operating. Following the 
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned 
in accordance with the regulations and standards 
in force. These  instructions can also be found at 
www.docuthek.com.

Explanation of symbols

 • 

,  1 ,  2 ,   

... = Action

 

= Instruction

Liability

We will not be held liable for damages resulting 
from non-observance of the instructions and non-
compliant use.

Safety instructions

Information that is relevant for safety is indicated in 
the instructions as follows:

 DANGER

Indicates potentially fatal situations.

 WARNING

Indicates possible danger to life and limb.

 CAUTION

Indicates possible material damage.

All interventions may only be carried out by qualified 
gas technicians. Electrical interventions may only be 
carried out by qualified electricians.

Conversion, spare parts

All technical changes are prohibited. Only use OEM 
spare parts.

Transport

On receipt of the product, check that the delivery is 
complete (see Part designations). Report any trans-
port damage immediately. 

Storage

Store the product in a dry place. Ambient tempera-
ture: see Technical data.

Disposal

Components, particularly batteries, are to be dis-
posed of separately.
On request, old units may be returned carriage paid 
to Elster GmbH in accordance with the relevant waste 
legislation requirements (for Germany: KrW-/AbfG 
[Act for Promoting Closed Substance Cycle Waste 
Management and Ensuring Environmentally Compat-
ible Waste Disposal]).

Operating instructions

Translation from the German

D

GB

F

NL

I

E

GB-1

Safety

Contents

Communications module ACM 

WAVE SYSTEM RF for gas meters 

with Absolute ENCODER AE2 with 

and without smart valve

Communications module ACM WAVE 

SYSTEM RF for gas meters with Absolute 

ENCODER AE2 with and without smart valve 1
Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Checking the usage . . . . . . . . . . . . . . . . . . . . . 2

Type code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Attaching the RECEIVER base plate. . . . . . . . . . 2
Wiring the RECEIVER. . . . . . . . . . . . . . . . . . . . . 3

Installing the gas meter  . . . . . . . . . . . . . . . . . . . 3

Attaching the TRANSMITTER. . . . . . . . . . . . . . . 3

Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . 4

Installing the TRANSMITTER/RECEIVER  . . . . . . 4
Synchronizing the TRANSMITTER/RECEIVER 

failed  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing the REPEATER  . . . . . . . . . . . . . . . . . . 4
Synchronizing the REPEATER with the 

RECEIVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Synchronizing the REPEATER with the 

TRANSMITTER. . . . . . . . . . . . . . . . . . . . . . . . . . 4

Synchronizing the REPEATER failed  . . . . . . . . . 4
Finishing installation . . . . . . . . . . . . . . . . . . . . . . 4
Closing and sealing the REPEATER . . . . . . . . . . 4

Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Assistance in the event of malfunction  . . . . . 5

Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . 6

Declaration of conformity . . . . . . . . . . . . . . . . 6
Contact  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Содержание ACM WAVE SYSTEM RF

Страница 1: ...ediately Storage Store the product in a dry place Ambient tempera ture see Technical data Disposal Components particularly batteries are to be dis posed of separately On request old units may be returned carriage paid to Elster GmbH in accordance with the relevant waste legislation requirements for Germany KrW AbfG Act for Promoting Closed Substance Cycle Waste Management and Ensuring Environmenta...

Страница 2: ...sidered as non compliant Type code Code Description ACM Absolute ENCODER communications module WAVE SYSTEM RF Radio system V Drive Smart valve control Part designations 2 1 6 3 5 7 4 1 Gas meter 2 Absolute ENCODER AE2 3 ACM WAVE TRANSMITTER RF 4 ACM WAVE RECEIVER RF with base plate 5 ACM WAVE REPEATER RF with base plate 6 Retaining screw 7 Calibration seal Installation Attaching the RECEIVER base ...

Страница 3: ...in During this time there is no communication with the other units of the ACM WAVE SYSTEM At the end of the charging time the green LED on the RECEIVER blinks every 10 s and the red LED blinks at a rate of 1 Hertz The charging time can be used for further in stallation work see page 3 Closing and sealing the RECEIVER and 3 Installing the gas meter Closing and sealing the RECEIVER Secure the RECEIV...

Страница 4: ...e units have found each other The green LEDs do not blink simultaneously See page 5 Assistance in the event of mal function 3 Confirm that both units have been synchronized To do this hold the permanent magnet on the LEDs on the REPEATER for approx 10 s The green LEDs on the REPEATER and the RECEIVER no longer blink simultaneously The red LED on the REPEATER now blinks at a rate of 1 Hertz The REP...

Страница 5: ...eck the connection cable see page 2 The green LEDs on the REPEATER and the RECEIVER do not blink simultaneously The REPEATER has found a foreign RECEIVER e g in a neighbouring room Hold the REPEATER closer to the RECEIVER If the REPEATER is too far away from the RECEIVER the green LED goes out The wireless link is too large To support the wireless link use an additional REPEATER Position the first...

Страница 6: ...R RF 5 min ACM WAVE TRANSMITTER RF ACM WAVE REPEATER RF Battery power supply battery service life 15 years The TRANSMITTER is designed for max 4 control commands per hour Smart valve Diaphragm meter BK G4 Ambient temperature 10 to 40 C Opening time from closed to open released state 4 s closing time 0 5 s Min inlet pressure 17 5 mbar Allowed leakage flow in the customers piping valve released max ...

Отзывы: