GB-6
D
GB
F
NL
I
E
Elster GmbH
Postfach 129, D-55248 Mainz-Kastel
Steinern Straße 19-21, D-55252 Mainz-Kastel
T +49 6134 605-0
F +49 6134 605-390
www.elster-instromet.com
Elster Metering Ltd.
Tollgate Business Park
Beaconside
Stafford, Staffordshire ST16 3HS
T +44 1785 275200
F +44 1785 275305
[email protected]
W
e r
eserve the right to make technical modifications
in the inter
ests of pr
ogr
ess.
Contact
Technical data
Enclosure: IP 54.
Ambient temperature: -25 to +55°C.
M-BUS transfer of status and error messages in
accordance with EN 13757.
ACM WAVE RECEIVER RF
Power supply via M-BUS: 6 mA (4 M-Bus loads).
Connection cable design: 2 m (other dimensions
on request), flexible, two-core cable LiYY, fireproof
pursuant to IEC 60332-1, Ø = 0.25 mm
2
.
The free cable end has 2 wire end ferrules.
Energy accumulator charging time:
ACM WAVE RECEIVER RF: < 5 min.
ACM WAVE TRANSMITTER RF,
ACM WAVE REPEATER RF
Battery power supply,
battery service life: 15 years.
The TRANSMITTER is designed for max. 4 control
commands per hour.
Smart valve
Diaphragm meter BK-G4
Ambient temperature: -10 to +40°C.
Opening time from closed to open/released state:
≤ 4 s,
closing time: ≤ 0.5 s.
Min. inlet pressure: 17.5 mbar.
Allowed leakage flow in the customers’ piping:
valve released:
max. 13 l/h at 35 mbar ∆p,
valve closed: 5 l/h.
Declaration of conformity
We, the manufacturer, hereby declare that the ac-
cordingly labelled products Absolute ENCODER AE2
with communications module ACM WAVE SYSTEM
RF, ACM WAVE SYSTEM RF V-Drive and ACM WAVE
REPEATER RF for gas meters BK-G comply with the
requirements of the listed Directives and Standards:
Directives:
– 2004/108/EC, 1999/5/EC.
Standards:
– EN 61000-4-2, EN 61000-4-3, EN 301489-3,
EN 60950-1, EN 300220-2.
The production is subject to the stated Quality System
pursuant to DIN EN ISO 9001, TÜV NORD CERT.
Elster GmbH
Scan of the Declaration of conformity (D, GB) – see
www.docuthek.com