![Elster Instromet DL230 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/elster-instromet/dl230/dl230_operating-manual_2396884025.webp)
Technical
data
25
3 Technical data
3.1 General data
Data
Value
Unit
Width (incl. antenna cover)
250
mm
Height (incl. cable glands)
175
mm
Depth
85
mm
Permissible ambient temperature range
-25 ... +60 °C
3.2 Power supply for the DL230 without integrated power
supply unit
3.2.1 Battery power supply for the basic device
Data
Value
Unit
Voltage
3.6
V
General nominal capacity
16.5
Ah
Usable capacity
13.0
Ah
Minimum number of batteries required
1
units
Minimum operating life (at standard
measurement conditions)
8
years
The
standard measurement conditions
are defined as follows:
Data
Value
Measurement cycle
900 seconds
Mode input 1 to 4
Pulse input
Display active
60 minutes per month
Interface or modem active
30 minutes per month
Ambient temperature
-10 ... +50°C
Содержание DL230
Страница 1: ...Operating manual Data Logger DL230 ...
Страница 2: ...Data Logger DL230 Operating manual 73022387 Issue b Issue date 11 11 2014 Software version from 1 01 ...
Страница 8: ......
Страница 47: ...Assembly Connection and Putting into Operation 47 Position of the key to open the calibration lock ...
Страница 105: ...Appendix 105 English manual 73 022 387 ...
Страница 106: ...106 Appendix 9 2 EC Declaration of Conformity ...
Страница 107: ...Appendix 107 9 3 ATEX Type Examination Certificate 9 3 1 Associated apparatus for Zone 0 1 ...
Страница 108: ...108 Appendix ...
Страница 109: ...Appendix 109 ...
Страница 110: ...110 Appendix ...