7.4
How to troubleshoot not cooling problems
Follow the chart below to troubleshoot problems of the vending machine not cooling. That is, the vending
machine or product is warm. If the ems controller is the saving mode, shows ---, then the product is at a higher
temperature.
product warm
Is the controller
on and display
illuminated?
Is power
available at the
controller mains
connector?
Replace
controller
No
Yes
Is the
compressor LED
on?
Yes
Is compressor
running?
Yes
Is power
available at
controller
compressor
connector?
Refrigeration
system fault
Yes
No
Compressor
fault
No
Yes
Check wiring and
fuses
No
Is the controller
showing another
fault?
See alarm
troubleshooting
Yes
No
Replace
controller
No
Is the
mechanical
thermostat
working?
Yes
Replace
mechanical
thermostat
No
Replace controller