Technical Information
elson BUSHPEX Pull-On
Underground Installa�on
NOTE
: It is a requirement to pressure test the pipe and
fi�ngs in accordance with AS/NZS
3500 prior to burying or
concealing the elson BUSHPEX Plumbing System.
Un
derground installa�on of elson BUSHPEX Pull-On pipe
and fi�ngs must be in accordance with AS/NZS
3500
including but not limited to the following :
• Minimum buried depth required by standards.
•
Minimum pipe separa�on distance.
•
Wrapping and protec�on.
•
Conduit sleeving through slab penetra�on.
•
Underground Piping installa�on recommended with no
joints.
•
Concrete slab piping must be con�nuous with no joints.
• Conne
c�ng Barb soldered connec�on require special
a�en�on. Solder the brass connec�on barb first then
allow to cool before join�ng.
• In a
ccordance with AS/NZS
3500 regions with extreme
hot or cold temperatures require appropriate product
selec�on and/or insula�on for protec�on and
compliance. Considera�on should also be given to
insula�ng the pipe for energy efficiency as well as the
preven�on of condensa�on which can occur in hot
and cold lines.