25
6. Shading position
After the setting of the sending of meteorological and automatic data, you may
now teach in a shading position.
You may determine an individual position for awnings or blinds up to which the
shading is extended in automatic mode. In case of blinds with slats, an additional
aperture angle of the slats may be determined (reversing).
Select the desired step with the
key:
(continue) in order to skip the setting of the shading position. The
shading is then always completely extended by the automatic
(closed). In this case, continue as described in chapter „7. Saving
basic settings”.
(learn) in order to teach in the shading position.
(clear) in order to delete an already taught in shading position. The
shading is then always completely extended by the automatic
(closed). In this case, continue as described in chapter „7. Saving
basic settings”.
Confirm your selection with the
key.
Note:
After switching from manual to automatic mode, the drive remains in the
position set manually. If the conditions for automatic shading
are not met
, the
control retracts the hangings at the end of the retraction delay. If the conditions
for shading
are met
, the control at first retracts the hangings at the end of the
extension delay (4-minute reference movement). After that the shading position is
initiated.