Installation and commissioning

RF-Router-N

 • Version: 10.05.2016 • Technical changes and errors excepted.

2.3. Connection

The radio router is plugged into a mains socket (CEE 7/4). The mains voltage must be 
230 V AC / 50 Hz.

Install and use only in dry interior rooms. 

Avoid condensation.

Do not expose to continuous sun radiation 

to avoid overheating. 

The housing is not UV-resistant.

The 

Radio Router N

 is taught-in for the controller like a radio actuator. In the menu 

System > Installation > Radio connection > RF Router > Status 

other radio clients that have already been taught-in are assigned to the router. Their 
radio signal is then routed through the 

RF-Router-N

 if the transmission path is too 

long for a direct connection.

2.3.1. Radio communication schema

Radio actuators (ventilators, relays, motor control units ...) can only be operated with 
the remote control Remo 8 

via the controller

. They can 

not

 

be additionally

 switched di-

rectly with the remote control.

2.4. Notes on mounting and commissioning

Device must not be exposed to water (rain). This could result in the electronic being 
damaged. A relative air humidity of 95% must not be exceeded. Avoid bedewing.

Controller

Remote control

Remo 8

Motor control unit

RF-MSG (motor control unit)

RF router

Ventilation device

WL610

RF relay

Remote control

Remo 8

Radio communica-
tion 

directly

 with 

the Controller: 

Radio communica-
tion with the control-
ler 

via RF Router

:

This device must also 
be taught-in at the 
controller.

Содержание RF-Router-N

Страница 1: ...tructions Part number 60529 Elsner Elektronik GmbH Control and Automation Technology Sohlengrund 16 D 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de EN Technical Service 49 0 70 33 30 945 250 ...

Страница 2: ...ury caused by components moved automatically If the wireless connection between the control unit and the wireless actuator is interrupted connected devices can no longer be operated For that reason do not connect drives to the wireless actuator which could be hazardous to human life 1 1 Technical specifications The product is compliant with the provisions of EU guidelines 1 2 Deliverables Router i...

Страница 3: ...supplier immediately The device may only be used as a fixed site installation that means only when assem bled and after conclusion of all installation and operational start up tasks and only in the surroundings designated for it Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions 2 2 Notes on wireless equipment Wh...

Страница 4: ...uted through the RF Router N if the transmission path is too long for a direct connection 2 3 1 Radio communication schema Radio actuators ventilators relays motor control units can only be operated with the remote control Remo 8 via the controller They can not be additionally switched di rectly with the remote control 2 4 Notes on mounting and commissioning Device must not be exposed to water rai...

Страница 5: ...rately before installation 1 Put the control unit into teaching mode observe the corresponding manual data sheet 2 Plug in the RF router The device learns a connection to the control unit on its own 3 seconds after the mains voltage is applied Only one radio client can be recog nised at a time Observe the response from the control system device taught The procedure for assigning radio clients to t...

Отзывы: