Cause:
No radio connection between operating unit and weather station. The
weather station is out of order (e.g. has no voltage) or the radio connection is
interrupted or has not yet been taught in.
Action:
The error may only be corrected by a qualified person for
electronics. Therefore, please contact your fitter.
The teaching in of the radio connection between weather station and operating
unit is described in chapter "1. Radio connection to weather station”.
Error:
instead of outdoor temperature or
instead of indoor temperature
Cause:
The outdoor temperature sensor of the weather station or the indoor
temperature in the operating unit is defect.
Action:
The error may only be corrected by a qualified person for
electronics. Therefore, please contact your fitter.
Error:
instead of lightness or
instead of wind speed
Cause:
Lightness sensor or wind sensor of the weather station are defect.