1.3 MAINTENANCE
:
Maintenance should be performed at least every six months. If it is used in high traffic area, a more
regular maintenance should be performed.
Disconnect the power supply
:
(1)
Clean and lubricate the screws, the pins and the hinge with grease.
(2)
Check the fastening points are properly tightened.
(3)
Check and make sure that the wire connections are in good condition.
Connect the power supply
:
(1) Check the power adjustments.
(2) Check the function of the manual release.
(3) Check the photocells or other safety device.
Hydraulic Oil
:
Recommended Hydraulic oil:
SHELL TELLUS T22
Remove the two screws to access the tank.
Begin by adding small amounts of oil while the motor is running.
Add oil only in one of the holes as the other one hole lets the air escape. Run the motor 10-
15 times to let the oil circulate.
The oil level should be checked with the motor in idle position, inclined at about 5 cm and with
the shaft fully inside as in the photo. With this inclination the oil must be visible from the two
holes.
Tighten both screws after the oil has been filled.