Description of the menu options
ELSA LANCOM DSL/10 Office
R29
Setup/Charges-module
This menu item is used to make the required settings for charge protection.
The default setting for charge protection is 10 hours per six days. The menu has the
following layout:
Every charge unit incurred by a connection is immediately deducted from the minute
budget, enabling monitoring of the minutes still available.
Day(s)/Period
This menu option allows you to define a period of time in days (0 to 255) during which
the online minutes are to be added up and compared to the budget. The default setting
is six days. When this period has expired, the adding up of online minutes starts over
again.
If the value 0 is entered, a connection can no longer be established after the minutes
budget has been used.
Minutes budget
This option allows you to define the number of charge monitoring online minutes that are
to be available. These minutes can only be entered in increments of ten, with a maximum
total of 2550. The default setting is 600.
You can cancel a charge lock either by switching the device off and on again, by
activating the
Boot-system
option in the
Other
menu or by entering a new charges
budget.
This table can be used only for setting the budget units; all other entries are
automatically managed by the system.
Entering zero budget minutes deactivates charge monitoring.
/Charges-module
Charge management settings
Day(s)/Period
Length of one period in days
Minutes budget
Minutes available for each period
Spare-minutes
Remaining number of available minutes
Router-minutes
Number of minutes used by the router modules
Time-table
Local budget settings for the individual interfaces