Technical Manual MiniMEP Data Loggers

page 13

 Technical Data

Unit is suitable for storage (S), ambient conditions (A),
accuracy level (1)

Supply voltage ................... 230V / 50-60Hz

US-versions (2)xxx ......... 115V / 60Hz

Version 424/12V ............ 12V DC

Power consumption ........... app. 5VA max.

Ambient temperature ......... 0...+50°C (32...+122°F)

Inputs ................................. max. 4 x TF 501
Inputs MiniMEP x34 A ....... 2x 4...20mA, 2x TF 501

Digital- (Report-) inputs ..... 3x mains phase with adjustable

name and time delay

Version 424/12V ............ 3x +12V DC

Calibration ......................... factory set, maintenance free

Display resolution .............. -160...+60°C = 0,1K

-256...+140°F = 0,2°F

Protocol resolution ............. -110...-50°C = 0,5K

-50...+100°C

= 0,1K

+100...+150°C

= 0,5K

+150...+300°C

= 1,0K

+300...+600°C

= 2,0K

-166...-58°F

= 1°F

-58...+212°F

= 0,2°F

+212...+302°F

= 1°F

+302...+572°F

= 1,8°F

+572...+1112°F = 3,6°F

0...100% = 0,1%

Storage intervals ............... 1/2/3/4/5/6/10/12/15/20/30/60 min.

Outputs .............................. Buzzer, 1x alarm relay (SPDT),

isolated, 4A / cos phi=1/250V

Interfaces ........................... RS 232, RS 485

Accu interface .................... Charge controller for 1,3 Ah Lead Accus

(not types 404 S, 2404 S, 424/12V)

Data memory ..................... see type overview

Real time clock .................. automatic summer/winter shift,

can be disabled

Data storage ...................... unlimited, clock backup typ. 10 years

Housing

4xx-types ........................ plastic, wall mounting, IP 54
5xx-types ........................ plastic, panel mounting,

IP 54 from front

 Supplied accessories 

(2)4xx types

z

This manual

z

1 x Fitting PG 9

z

1 x Fitting PG 11

z

1 x Fitting PG 13,5

z

3 x Screws 4 x 40

z

3 x Dowels 6mm

 Not supplied accessories

Temperature Sensors

z

TF 501/5M, diam. 6 mm, 5 meters shielded cable
TF 501/10M, diam. 6 mm, 10 meters shielded cable
TF 501/15M, diam. 6 mm, 15 meters shielded cable
Attention! only suitable up to 80°C !

Humidity Sensors

z

FF 2520, humidity transmitter with 4/20mA output, must be
supplied by an external AC-adaptor.

Please note installation information !

z

MiniMEP PC-software "CV-Scheduler"

z

External Accumulator or Accu-set

z

PC-cable (see text)

Содержание MiniMEP 2404S

Страница 1: ...minute interval Example 2 6 years with a 15 min interval z Data storage is unlimited even without mains voltage z Real time clock with typ 10 years battery backup z Continuous recording by external le...

Страница 2: ...4A 534A canrecord2temperature values and the values of two 4 20 mA humidity transmitters Type Housing Inputs Recording Digital Alarm Limits LC Input for Memory Cap Supply Overview Range inputs Alarm r...

Страница 3: ...01 07 96 14 15 sensor 2 21 0 C 01 07 96 14 30 01 07 96 14 45 01 07 96 15 00 P P MINIMEP serial no 000000 01 07 96 14 30 01 07 96 15 00 01 07 96 14 45 correction probe selection push for longer than 1...

Страница 4: ...abled during accu operation Real time clock The integrated x tal controlled real time clock can be corrected by only 24 hours Theautomaticsummer winter shiftcanbedisabledforexportpurposes Without main...

Страница 5: ...delay is run down an alarm message will be generated 0 01 4 00 h min 1 00 h min name transm 3 individual name for this probe input max 8 characters see table transmitter 3 probe 4 corr 1 the last fou...

Страница 6: ...l be generated 0 01 4 00 h min 1 00 h min name probe 3 individual name for this probe input max 8 characters see table probe 3 probe 4 corr 1 the last four corrections of this input with time to date...

Страница 7: ...mains ph L report input 2 al2 mains ph alarm relay N O contact Mains neutral alrm relay N C contact alarm relay common PE 1 2 3 4 5 6 7 8 9 RS 232 Interface MiniMEP 4xx RS 232 interface connector The...

Страница 8: ...14 input 1 4 20mA 15 input 1 4 20mA 16 probe 2 17 probe 2 com 18 input 3 4 20mA 19 input 3 4 20mA 20 probe 4 21 probe 4 com 22 n c 23 RxD RS 232 24 GND RS 232 25 TxD RS 232 51 R 51 R 11 13 15 17 19 21...

Страница 9: ...t A don t need the cables between terminals 37 and 38 TxD data out RxD data in 1 4 2 3 5 Stecker SUB D 9 polig male 7 6 9 8 GND 31 32 16 17 to controller unit PE Mains N Mains Line L Input 1 L Input 2...

Страница 10: ...16 17 18 19 ELREHA 63 47 34 35 36 37 38 34 35 36 37 38 93 105 L Eing 1 NK L Eing 2 TK L Ein 3 T r Dimensions of MiniMEP 4xx types Dimensions Terminals of MiniMEP 2 524 A 2 534 A Operating Unit Verbin...

Страница 11: ...ler an unlock code must be entered while start up You get this unlock code with the software please see software manual for further information Without this code retrieve and processing of data with t...

Страница 12: ...y please contact the manufacturer first Electrical installation and putting into service must be done from authorized personnel Please note the local safety instructions Before installation Check the...

Страница 13: ...m relay SPDT isolated 4A cos phi 1 250V Interfaces RS 232 RS 485 Accu interface Chargecontrollerfor1 3AhLeadAccus not types 404 S 2404 S 424 12V Data memory see type overview Real time clock automatic...

Страница 14: ...heir companies copy We state the following When operated in accordance with the technical manual the criteria have been met that are outlined in the guidelines of the council for alignment of statutor...

Страница 15: ...Drilling template MiniMEP x422 x424 Ma stab 1 1 scale 1 1 116mm 4 57 Bohrer Drill 6mm 24 7mm 27 Bohrer Drill 6mm 24 11 43 163 5 6 42 155 6 1 65mm 2 56...

Отзывы: