background image

 

 

 TZM443

                                        4x4 HIGH RES. & AUDIO MATRIX

 

ELPRO Video Labs s.r.l.

 

Via della Praia, 4/A   10090 Ferriera di Buttigliera Alta (TO) ITALY 
Tel.+39 0119348778 – Fax +39 0119348779

 

 

 

TZM443-M    26/10/2005 

• 

Variable time “through blank” switching 

• 

Keypad programmable preview output 

• 

Customizable default configuration 

• 

4 presets recallable from keypad, 8 from RS232 

• 

RGBHV only, AUDIO only, AFV 

• 

RS232, RS485 control, IR 

• 

Infrared remote control (optional)

 

 

Содержание TZM443

Страница 1: ...lta TO ITALY Tel 39 0119348778 Fax 39 0119348779 1 TZM443 M 26 10 2005 Variable time through blank switching Keypad programmable preview output Customizable default configuration 4 presets recallable...

Страница 2: ...ical data 10 0 Notes Please read this manual carefully when installing the TZM443 unit The manufacturer will not be responsible for any damage caused by the use although correct of its products The in...

Страница 3: ...atrix for RGBHV high resolution signals with associated stereo audio signal It can be controlled with the integrated keyboard from the computer with an RS232 or RS485 serial interface and with an infr...

Страница 4: ...d out by highly skilled personnel who must be informed on risks concerning electric shock In some nations it is necessary to change the plug in order to adapt it according to the local standard types...

Страница 5: ...t configuration or according to the last preset recalled from the keypad or computer CAUTION To store and enable a configuration to the next switch ons customized default configuration press the MODE...

Страница 6: ...The TZM443 features the through blank switching mode The switching time is user adjustable to permit the perfect matching with the destination device This important feature prevents annoying effects...

Страница 7: ...a particular setup Button Function Button Function Mode Input1 Save status 1 Mode Output1 Recall status 1 Mode Input2 Save status 2 Mode Output2 Recall status 2 Mode Input3 Save status 3 Mode Output3...

Страница 8: ...isabled by holding down during startup the MODE button on the front panel of the TZM443 The TZM443 has been factory set with remote control enabled The following functions can be carried out with the...

Страница 9: ...ialogue via RS232 includes the following procedure 8 data bits no parity 1 stop bit speed at 9600 bauds 7 1 Connections Connections must be made with a cable according to the attached diagram TZM443 4...

Страница 10: ...ance If ZZ is 00 the audio output will be brought to 0 Volt Example to switch the video of input 1 and the audio of input 3 to output 4 it is necessary to send the following characters in line 42 30 3...

Страница 11: ...5 Status Request The host must be sent with the following sequence D followed by CR where D is the character Hex 44 The matrix responds YY Video input on bus 1 from 01 to 04 ZZ Audio input on bus 1 fr...

Страница 12: ...cuted correctly NACK Hex 15 if it has found incorrect transmission errors 7 7 Recall of a Preset It is possible to enable a previously stored status The host must be sent with the following sequence R...

Страница 13: ...put on bus 1 from 01 to 04 ZZ Audio input on bus 1 from 01 to 04 YY Video input on bus 2 from 01 to 04 ZZ Audio input on bus 2 from 01 to 04 YY Video input on bus 3 from 01 to 04 ZZ Audio input on bus...

Страница 14: ...57 30 33 32 0D 7 11 Through blank switching time request The host must send the following sequence w followed by CR where w is the character Hex 77 The matrix responds Y time set for output 1 from 0 t...

Страница 15: ...e audio mute video mute or audio video mute on the preview output The host must send the following sequence mX followed by CR where m is the character Hex 6D X indicates the type of mute for the previ...

Страница 16: ...will respond ACK Hex 06 if the control has been executed correctly NACK Hex 15 if it has found incorrect transmission errors Example in order to program the TZM443 connected as a unit with address 4 b...

Страница 17: ...nected to the 485 Bus The serial connection features are 8 data bits no parity 1 stop bit speed that can be set at 2400 or 9600 bauds The transmission speed the address of the unit and the response ti...

Страница 18: ...iagram Caution If several units are daisy chained the 100 ohm termination must be placed on the last unit TZM443 4x4 HIGH RES AUDIO MATRIX ELPRO Video Labs s r l Via della Praia 4 A 10090 Ferriera di...

Страница 19: ...ing a preset recall of a preset firmware release identification request global mode request set through blank switching time through blank switching time request set preview output mute setup on previ...

Страница 20: ...ir faulty units with free delivery at its facility in Turin The repair will be charged to the customer For any information during the installation of the TZM443 please call Elpro s hot line 011 934877...

Отзывы: