EN - 65
liberoCONFIG
LI6002Eg
EXAMPLE - TRANSPORTATION
5
5.3.3
PDF report at any USB port
5.3.3.1
Start - PDF
As soon as the data logger is connected to an USB-port, the PDF report will be created.
5.3.3.2
End - PDF
After the PDF report has been created, LIBERO Tx returns to normal data logging.
5.3.4
Error Messages
5.3.4.1
On the display
s.e.
Sensor input temporarily short-circuited
n.c.
Sensor temporarily disconnected or there is a bad connection (loose contact) between the
data logger and the sensor.
5.3.4.2
In the PDF-Report
WARNING: Device
error
Has an error occurred during logging and the data logger did reset, this warning is printed
above the graphic in bold.
WARNING: Sensor
error
If a sensor short circuit or disconnection was detected this warning is printed above the
graphic in bold.
• LIBERO Tx have the feature to create a, PDF report which could be printed
out on any printer.
• Data logging continuous during the creation of the PDF report.
A LIBERO PDF REPORT IS A PDF/A ISO STANDARD FILE
ONLY OPEN THE FILE WITH A PDF READER
Always save the LIBERO PDF file directly and without opening it or send it as an
e-mail attachment. Opening and saving the PDF file with a PDF editor can make
embedded data unusable for subsequent processing with elproVIEWER,
elproASSISTANT or liberoMANAGER. The integrity of a PDF report can be
checked with the "Check PDF file integrity" function in liberoCONFIG. The men-
tioned software components run this check automatically.