15. Troubleshooting

        Problem

 Potential cause

   Remedy

Red LED lights and a tone sounds 12
times in sequence. Then the green
LED blinks and a signal tone sounds
every 7 seconds.

Door for the safe is not properly closed.

Close the door properly and press
any digit button. See Section 3:

Closing the electronic lock

.

Twelve high-pitched tones and the
RED lights.

Incorrect entry of a master or user
combination or error in a programming
sequence.

Check the combination. Enter a
valid combination. See Section 4:

Time-out following erroneous
entries

.

Or carry out programming
correctly. See Section 10:

Programming the electronic lock

.

Lock does not respond to any entries
at all.

Invalid master or user combinations have
been entered three times in sequence.
The time-out period following errors has
been activated.

Enter a valid master or user
combination once the lock-out
period has elapsed. See Section
4: 

Time-out period following

erroneous entries

.

Ten high-pitched warning tones, the
red and green LEDs blink 10 times
alternately.

Battery is weak. The low battery warning
has been activated.

Install a new battery. See
Section 6: 

Charge monitoring;

replacing the battery

.

Green LED blinks every five
seconds; the electronics do not
respond to any keypad entries.

A timed delay period has been
programmed.

See Section 10.4.1: 

Opening the

lock with the timed delay function
activated

One high-pitched tone and the green
LED blinks once, followed by one low-
pitched tone and the red LED blinking
once.

Manipulation indicator: The keypad has
been changed out or invalid
combinations were entered three times
or the battery has been replaced.

Enter the combination once again.
See Section 9: 

Detecting keypad

replacement and tampering

.

Keypad does not respond.

A timed delay period is running.

Wait until the timed delay period
has elapsed. See Section 10.4:

Programming a timed delay
period

.

Keypad does not respond.

The battery is dead.

Connect an emergency power
battery. Applicable only for
keyboard model 7233. See
Section 6: 

Charge monitoring;

replacing the battery

.

The lock cannot be opened once the
timed delay period has elapsed.

Release period has also elapsed.

Observe the release time
window, which will be from 30
seconds to 2 minutes, depending
on the timed delay period which
was programmed. See Section
10.4: 

Programming a timed delay

period (Explanation)

Beep signal at five-second intervals
for a period of 60 seconds

A combination interlock has been
programmed. The second
combination will have to be entered.

Enter the second combination
within the 60-second period.
See Section 10.3.1: 

Opening the

lock with the combination
interlock feature activated

.

Keypad does not respond.

A time-lock period has been
programmed.

Wait until the programmed time-
lock period has elapsed. The
lock can then be opened with the
master combination or a user
combination. See Section 10.9:

Programming a time-lock period

.

Programming of I/O-function
not possible.

Power safe mode still activated.

Deactivate power safe mode.
See Section 10.6: 

Programming of

I/O function.

Содержание 7215

Страница 1: ... A series of digits required to open the lock It comprises the User number and combination e g master combination 0 _ 6 5 4 7 2 1 e g user combination 3 _ 8 7 9 5 8 3 Factory combination The initial combination programmed at the factory For this electronic lock the combination has been pre set to 0 _ 1 2 3 4 5 6 Master combination Combination used by the master to open the lock User combination Co...

Страница 2: ...ed with the C button The red LED blinks every five seconds during the time out period The end of the time out period is indicated by the green LED blinking and a single low high signal It is now necessary to enter a valid combination twice in order to open the electronic lock This is done by connecting the new battery 9 volt alkaline to the emergency contacts located at the keypad Important Observ...

Страница 3: ...the door If the model 7216 3XX X or 7217 3XX X electronic lock has been opened under motor power then it cannot be closed with the emergency release key 7 1 Closing after emergency release 7216 7217 Rectify the problem Close the emergency release feature enter the master or user combination and then press any digit key 7 2 Closing after emergency release 7216 3XX X 7217 3XX X Close the emergency r...

Страница 4: ... the 6 digit master or user combination e g Confirm the entry Enter the new 6 digit user combination e g Confirm the entry Enter the new user combination again to confirm Confirm the entry Cancel A maximum of 9 user combinations can be programmed 9 8 7 6 5 4 The previous user combination will be retained if there is an error in programming UNo 1 UNo 9 User 9 Override combination Green LED blinks o...

Страница 5: ...umber see example below Once the first user combination has been entered a beep will sound every five seconds for a period of 60 seconds If the second user combination is not entered within this 60 second period then the entry will be discarded and both user combinations will have to be entered again Example Button for UNo 1 Button for UNo 2 etc through to button for UNo 9 Function Operation butto...

Страница 6: ...y digit button 10 4 Programming a timed delay period Possible only with the electronic lock open and only with the master combination It is possible to program a release period in combination to the time delay periode The release periode is set to 1 Minute on factory suply For reprogramming see 10 5 Explanation Timed delay period Period from entering a combination the first time to clearance for e...

Страница 7: ...onfirm the entry Enter 6 digit master combination e g Confirm the entry Activating of power safe mode Confirm the entry Cancel Comments Green LED blinks once OK green LED lights and low high tone sounds Error 12 high pitched tones and red LED lights Close the lock Press any digit button Programming I O functions Programming is possible with the electronic lock closed or open and only with the mast...

Страница 8: ...d LED lights IMPORTANT After the function is deleted the lock will automatically close one more time after 10 seconds have elapsed Can be programmed only with the electronic lock open and only with the master combination 10 8 Programming an override combination An override combination permitting immediate opening even if a time lock period has been specified can be set up for the first time only b...

Страница 9: ...hour to 99 hours Comments Green LED blinks once OK green LED lights and low high tone sounds Error 12 high pitched tones and red LED lights Following the final entry confirmation the electronic lock will respond to no keyboard commands whatsoever during the specified time lock period After the programmed time lock period has elapsed the electronic lock may be opened with the master combination or ...

Страница 10: ... can be obtained from CARLWITTKOPP GmbH KG Sternbergstr 5 D 42551 Velbert Germany Phone 49 2051 95660 Fax 49 2051 956666 or INSYS Waffnergasse 8 D 93047 Regensburg Germany Phone 49 941 560061 Fax 49 941 563471 Descriptions of the functions and operating instructions are included with the PC software 14 Reset function This programming option returns all the programmed functions to the factory defau...

Страница 11: ...gh pitched tone and the green LED blinks once followed by one low pitched tone and the red LED blinking once Manipulation indicator The keypad has been changed out or invalid combinations were entered three times or the battery has been replaced Enter the combination once again See Section 9 Detecting keypad replacement and tampering Keypad does not respond A timed delay period is running Wait unt...

Страница 12: ... improper treatment nor in the event of losses to property or assets due for example to a failure to close the safe properly We recommend obtaining appropriate insurance coverage to protect the contents of your safe Your property insurance sales agent can provide details If the safe cannot be opened even though you have followed the instructions given above then kindly contact the safe manufacture...

Отзывы: