Clearing faults and malfunctions
66
Malfunction
Possible cause
Troubleshooting
Rust in the baking
chamber
The water quality is
poor.
Use a water filter or
replace the water
filter currently in
use.
The wrong cleaner has
been used.
Always use Eloma
special cleaner.
Cleaner was not rinsed
out carefully.
Always rinse
thoroughly.
Iron parts in the water
supply
Remove or replace
all water
components made
of untreated steel
provided by the
operating company.
Water drips from the
device door.
Door seal worn or
damaged.
Replace the door
seal.
Inform the
customer service
department.
Backmaster EB 30
MT
/
EB 30 XL
MT
does not
heat up.
Show mode is switched
on.
Switch off show
mode.
Tab. 12:
Description of faults, possible causes and measures