elna 9900
33
Replacing the Lateral Moving Unit
To remove:
1. Remove the spool stand, static head cover (right),
right cover and left cover (see pages 4 and 5).
2. Remove the tension unit cover (see page 4).
3. Remove the three setscrews (A) and remove the
driver cover.
4. Disconnect the connectors.
5. Remove the two setscrews (B) and remove the lateral
moving unit.
To attach:
6. Attach the lateral moving unit and loosely fix it with the
2 setscrews (B).
7. Push the needle bar down and rotate the handwheel
to set the index disk at “L”.
8. Adjust the position of the lateral moving unit so the
needle enters into the center of the hole in the needle
plate. Tighten the 2 set screws (B) securely.
9. Connect the connectors and attach the parts removed
in steps 1 to 3.
Setscrews (A)
Connector
Setscrews (B)
Connector
Hole in the needle plate
Needle