16
elna 9900
Replacing and Adjusting the Presser Foot (1)
1. Remove the lower thread guide plate unit and
thread catcher panel.
2. Loosen the needle clamp screw and the setscrew.
Remove the needle, needle clamp and two
needle clamp cushions.
NOTE:
The presser foot will spring down when the needle
clamp is removed.
3. Remove the setscrew and replace the presser
foot.
4. Attach the needle, needle clamp and needle
clamp cushions. Tighten the needle clamp
screw and setscrew.
5. Adjust the needle height. (see To Adjust the
Needle Height)
6. Push the needle bar down to engage the
needle bar clutch.
Needle clamp
cushion
Needle clamp
screw
Setscrew
Presser foot
Setscrew
Needle clamp
Содержание 9900 - LEAFLET