FUNKCE MENU ČÍTAČE
9.3.7
Measured value
Function setting
Configuration of bargraph - BARGF
Function BARGF parameters
B-IN
Setting of input possibilities to bargraph
Options:
IN-1
-
Measured value of current input signal
IN-2
-
Measured value of pulse input signal
SUM-1
-
Sum 1
SUM-2
-
Sum 2
ALA-1 -
Range and input variables are determinable in ALA-1
ALA-2 -
Range and input variables are determinable in ALA-2
ALA-3 -
Range and input variables are determinable in ALA-3
ALA-4 -
Range and input variables are determinable in ALA-4
str
Setting of bargraph range start
This parameter is used for setting the bottom limit of bargraph range. When measured value drops
to bottom limit of set range, all bargraph LEDs stop flashing.
end
Setting of bargraph range end.
This parameter is used for setting the top limit of bargraph range. When measured value
reaches top limit of set range, all bargraph LEDs start flashing.