FUNKCE MENU ČÍTAČE
Measure value
Function setting
9.3.5
Configuration of analogue output DACO
STR and END menu items are used only when IN-1, IN-2 a SUM-1, SUM-2 are set in DACO->IN. Other items
ALA1-ALA4 are using other range setting (determined as shown in description above) param. STR and END
doesn‘t appear in menu DACO.
If analougue output is not connected, menu DACO is not displayed
.
Example:AP11 counter with single relay module and analogue output :menu item DACO->IN will contain only
options: IN-1, IN-2, SUM-1, SUM-2, ALA-1, ALA-2
Function DACO parameters
IN
Setting of input possibilities to analogue output
Options:
IN-1
-
Measured value of current input signal
IN-2
-
Measured value of pulse input signal
SUM-1
-
Sum 1
SUM-2
-
Sum 2
ALA-1 -
Range and input variables are determinable in ALA-1
ALA-2 -
Range and input variables are determinable in ALA-2
ALA-3 -
Range and input variables are determinable in ALA-3
ALA-4 -
Range and input varibales are determinable in ALA-4
out
Type of analogue output
Options:
0-20
0 to 20 mA
4-20
4 to 20 mA
20-0
20 to 0 mA
20-4
20 to 4 mA
str
Start of analogue output range
end
End of analogue output range
PANEL METER MENU FUCTIONS