A.7.2
Velocity Loop
Feature Details
Controller type
PI
Velocity control
Fully digital
Programmable PI and FFW control filters
On-the-fly gain scheduling
Automatic, manual and advanced manual tuning
Velocity and position feedback
options
Incremental Encoder
Digital Halls
Interpolated Analog (sin/cos) Encoder (optional)
Resolver (optional)
Note:
With all feedback options, 1/T with automatic
mode switching is activated (gap, frequency and
derivative).
Velocity command options
Analog
Internally calculated by either jogging or step
Note:
All software-calculated profiles support
on-the-fly changes.
Velocity loop bandwidth
< 350 Hz
Velocity sampling time
140 - 200
μ
sec (x2 current loop sample time)
Velocity sampling rate
Up to 8 kHz; default 5.5 kHz
A.7.3
Position Loop
Feature Details
Controller type
“1-2-4” PIP
Position command options
Software
Pulse and Direction
Position loop bandwidth
< 80 Hz
Position sampling time
280 - 400
μ
sec ( x 4 current loop sample time)
Position sampling rate
Up to 4 kHz; default 2.75 kHz
Bassoon Installation Guide
0BTechnical Specifications
MAN-BASIG (Ver 1.4)
A-7