Feature
Details Connector
Location
Execution
time (all
inputs):
the time from
application of
voltage on
input until
execution is
complete
If input is set to one of the built-in functions —
Home, Inhibit, Hard Stop, Soft Stop, Hard and Soft
Stop, Forward Limit, Reverse Limit or Begin —
execution is immediate upon detection: 0 < T < 4 x
TS
If input is set to General input, execution depends
on program. Typical execution time:
≅
0.5 msec.
High-speed
inputs -
minimum
pulse width,
in high-speed
mode
T < 5
μ
sec
Notes:
Home mode is high-speed mode and can
be used for fast capture and precise
homing.
High speed input has a digital filter set to
same value as digital filter (EF) of main
encoder.
Highest speed is achieved when turning
on optocouplers.
G
e
ne
ral
i
n
pu
t re
tu
rn
Inp
ut
(
I)
Ri
n
=
2
.5K
V
z = 5
.1
V
Figure A-2:
Digital Input
Schematic
Bassoon Installation Guide
Technical Specifications
MAN-BASIG (Ver 1.4)
A-13