3.5.2
Connecting the Power Cables
The main power connector located at the bottom of the Bassoon, as follows:
Pin Function
Cable
Pin
Positions
AC
1
Main Voltage Phase 1
Power
AC
2
Main Voltage Phase 2
Power
PE Protective
earth
Power
AC
Motor
Cable
DC
Motor
Cable
PE Protective
earth
Motor Motor
M1 Motor
phase
Motor N/C
M2 Motor
phase
Motor Motor
M3 Motor
phase
Motor Motor
When connecting several motors, all
must be wired in an identical manner.
Table
3-2:
Connector for Main Power and Motor Cables
3.5.2.1
Connecting the Motor Cable
Connect the motor power cable
to the M1, M2, M3 and PE terminals of the main power
connector. The phase connection order is arbitrary because the Composer will establish the
proper commutation automatically during setup. However, if you plan to copy the set-up to
other drives, then the phase order on all copy drives must be the same.
Notes for connecting the motor cables:
For best immunity, it is highly recommended to use a shielded (not twisted)
cable for the motor connection. A 4-wire shielded cable should be used. The
gauge is determined by the actual current consumption of the motor.
Connect the shield of the cable to the closest ground connection at the motor end.
The forth wire should be used for the ground connection between the motor and
the second PE terminal of the Bassoon.
Be sure that the motor chassis is properly grounded.
A
A
P
P
M
M
M
Bassoon Installation Guide
Installation
MAN-BASIG (Ver 1.4)
3-9