![Elmo 95VDC Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/elmo/95vdc/95vdc_installation-manual_2394481020.webp)
Duo User Guide
MAN-DUOUG (Ver. 1.0)
3-8
3.8
The Main Power and Motor Power Connectors
Pin Function
Cable
Pin
Positions
PE Protective
earth
Power
PR Power
return
Power
PR Aux. Supply Input Return
Auxiliary
VP+ Pos. Power input
Power
VL Aux.
Supply
Input
Auxiliary
AC
Motor
Cable
DC
Motor
Cable
M3 Motor
phase
Motor Motor
M2 Motor
phase
Motor Motor
M1 Motor
phase
Motor N/C
PE Protective
earth
Motor Motor
Table
3-6:
Connectors for Main Power and Motors
3.8.1
Connecting Motor Power
Connect the motor power cable to the M1, M2, M3 and PE terminals of the relevant axis.
The phase connection order is arbitrary because the Composer will establish the proper
commutation automatically during setup. If several motor/drive combinations are designed
to operate in an identical manner, it is recommended to download the program into all the
drives and connecting them in the same way.
Notes for connecting the motor cables:
For the greatest immunity, it is highly recommended to use a shielded (not twisted)
cable for the motor connection. A 4-wire shielded cable should be used. The gauge is
determined by the actual current consumption of the motor.
Connect the shield of the cable to the closest ground connection at the motor end.
Be sure that the motor chassis is properly grounded.
Figure
3-3:
AC Motor Power Connection Diagram for each AXIS.
Содержание 95VDC
Страница 1: ...Duo Integrated Solution Installation Guide June 2007 Ver 1 0...
Страница 19: ...Duo User Guide MAN DUOUG Ver 1 0 3 7 3 7 Duo Block Diagram Figure 3 2 Duo Block Diagram...
Страница 23: ...Figure 3 6 Shared Supply Connection Diagram Duo User Guide MAN DUOUG Ver 1 0 3 11...
Страница 35: ...Duo User Guide MAN DUOUG Ver 1 0 3 23 Figure 3 6 Differential Auxiliary Input Option Block Diagram...
Страница 49: ...Duo Installation Guide MAN DUOIG Ver 1 0 A 4 A 3 Duo Dimensions...