32
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Fig. 11 Air filter
Maintenance and repair
D
Inlet flange
f
1
Mesh filter
s
1
Screws
U
Gas ballast valve (accessories of variant IV)
U
D
s
1
f
1
7.2.2 Air filter
WARNING
Risk of injuries due to rotating parts!
If the inlet flange has been removed, there will be the risk of injury on rotating parts
when reaching in.
Ø
Before demounting of the inlet flange, disconnect the pump from the power sup-
ply and secure it against accidental restart.
Ø
Do not reach into the inlet flange.
Ø
During disassembly/assembly make sure that not parts fall into the inlet flange.
WARNING
Danger of injury when dealing with compressed air!
When the filter is blown off with compressed air, loose solid particles or powder dust
swirling around may cause injury to the eyes. Inhaling can damage lungs.
Ø
Wear protective glasses and dust mask when cleaning the filter with compressed
air.
NOTICE
Property damage due to insufficient maintenance of the air filter!
Performance of the machine is reduced by a polluted air filter and insufficient mainte-
nance. This can cause damage of the machine.
Ø
Regularly clean the mesh filter.
Ø
Replace highly polluted or damaged mesh filters.
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]