Installation
5.4.1 Cooling water connection for continuous flow cooling
CAUTION
Risk of injury due to falling!
Fluid leakages can cause the floor to become slippery and persons can fall.
Ø
Check pump for loss of cooling water and leakages.
Ø
Wear non-slip shoes.
NOTICE
Property damage due to wrong coolant!
Dirt particles and aggressive water may lead to malfunctions or to premature wear in
the cooling system.
Ø
Only use pH-neutral, clean and filtered water for cooling.
NOTICE
Property damage due to improper operation!
Improper operation and wrong operating conditions can damage the machine.
Ø
The operating pressure of the cooling water must not exceed 6 bars.
Ø
The cooling water temperature must be between 15 and 45 °C.
the cooling water outlet (Fig. 2/D).
b) Check the pump for cooling water leakages.
Suitable cooling water
See Info "Recommended water quality", page 4