Installation
5.1 Preparation of installation
Ensure the following conditions:
• Machine freely accessible from all sides
• Do not close ventilation grids and holes
• Sufficient space for installing and removing pipes and for maintenance work, particularly for the installa-
tion and deinstallation of the machine
• No external vibration effects
• Do not suck any hot exhaust air from other machines into the cooling system
Oil filling point (Fig. 2/, 3/H, H
1
), oil sight glasses (Fig. 2/I, I
1
, 3/I, I
1
1
, 3/K,
K
1
), cooling water inlet (Fig. 2/C, 3/C) and cooling water outlet (Fig. 2/D, 3/D) must be easily ac-
cessible.
The cooling air inlets(Fig. 2/E, 3/E) and the cooling air outlets (Fig. 2/F, 3/F) must be
at least
30 cm
away
from the adjacent walls. Cooling air coming out must not be sucked in again.
5.2 Installation
NOTICE
Property damage caused by improper installation!
Improper erection and installation can damage the machine.
Ø
The machine may only be operated when it is set up horizontally
(Max. inclination: 8 ° in all directions).
Ø
Secure the machine against tipping over and falling.
Ø
The floor must be plane and even.
Ø
The bearing surface must be designed to be able to carry the weight of the
machine.
Ø
The non-return valve must not be removed.
An output reduction is noticeable when installed at more than 1000 m above sea level. In this case,
please contact us.
It is possible to install the machine on a firm base without anchoring. When installing on a sub-
structure we recommend fixing it with flexible buffers.